HPLC OF SYNTHETIC-POLYMERS .2. CHROMATOGRAPHIC CHARACTERIZATION OF COPOLYMERS FROM STYRENE AND ACRYLONITRILE

被引:19
作者
SCHULTZ, R [1 ]
ENGELHARDT, H [1 ]
机构
[1] UNIV SAARLAND,ANGEW PHYS CHEM,W-6600 SAARBRUCKEN,GERMANY
关键词
Adsorption chromatography of SAN copolymers; High performance precipitation chromatography; Solubility and adsorption; Styrene-acrylonitrile copolymers;
D O I
10.1007/BF02261298
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Statistical copolymers of styrene and acrylonitrile have been separated by high performance precipitation chromatography according to the increase in acrylonitrile content. The separation mechanism was strongly depending on the combination of stationary phase and eluent composition. By applying a typical normal phase gradient from n-heptane (precipitation) to dichloromethane the polymers were adsorbed, after dissolution of the polar groups of the stationary phases. The elution curves became broader with increasing acrylonitrile content of the polymer. By the addition of 20% methanol to the dichloromethane the adsorption could be minimized and copolymer elution was dependent solely on solubility and independent of stationary phase polarity. Separation according to chemical composition was also possible without precipitation with a large pore silica and a normal phase gradient from dichloromethane to the same eluent containing 2.75% methanol. © 1990 Friedr. Vieweg & Sohn Verlagsgesellschaft mbH.
引用
收藏
页码:325 / 332
页数:8
相关论文
共 21 条
[1]   PROPERTIES AND DIVERSITY OF C18 BONDED PHASES [J].
ENGELHARDT, H ;
DREYER, B ;
SCHMIDT, H .
CHROMATOGRAPHIA, 1982, 16 :11-17
[2]   UNUSUAL SIGNAL ENHANCEMENT IN REVERSED-PHASE CHROMATOGRAPHY OF POLYSTYRENE MONITORED BY UV-DETECTOR [J].
GLOCKNER, G ;
SCHMUTZLER, S ;
ENGELHARDT, H ;
SCHULTZ, R .
CHROMATOGRAPHIA, 1988, 25 (11) :983-988
[3]  
GLOCKNER G, 1983, MAKROMOL CHEM-RAPID, V4, P529
[4]   GRADIENT ELUTION CHROMATOGRAPHY OF POLYMERS ON REVERSED-PHASE COLUMNS WITH TETRAHYDROFURAN AS AN ELUENT COMPONENT [J].
GLOCKNER, G ;
VANDENBERG, JHM .
CHROMATOGRAPHIA, 1984, 19 :55-61
[5]   COPOLYMER FRACTIONATION BY GRADIENT HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
GLOCKNER, G ;
VANDENBERG, JHM .
JOURNAL OF CHROMATOGRAPHY, 1987, 384 :135-144
[6]   CHARACTERIZATION OF STYRENE-ACRYLONITRILE COPOLYMERS BY EXCLUSION CHROMATOGRAPHY AND TURBIDIMETRIC TITRATION OF THE FRACTIONS OBTAINED .2. INVESTIGATION OF A SAMPLE WITH BROAD CHEMICAL-DISTRIBUTION [J].
GLOCKNER, G ;
ALBRECHT, V ;
FRANCUSKIEWICZ, F ;
ILCHMANN, D .
ANGEWANDTE MAKROMOLEKULARE CHEMIE, 1985, 130 (MAR) :41-54
[7]   HP PRECIPITATION CHROMATOGRAPHY OF STYRENE-ACRYLONITRILE CO-POLYMERS [J].
GLOCKNER, G ;
KROSCHWITZ, H ;
MEISSNER, C .
ACTA POLYMERICA, 1982, 33 (10) :614-616
[8]  
GLOCKNER G, 1984, MACROMOLECULES, V17, P962
[9]   2-DIMENSIONAL ANALYSIS OF COPOLYMERS BY SIZE-EXCLUSION CHROMATOGRAPHY AND GRADIENT-ELUTION REVERSED-PHASE PRECIPITATION CHROMATOGRAPHY [J].
GLOCKNER, G ;
VANDENBERG, JHM ;
MEIJERINK, NLJ ;
SCHOLTE, TG ;
KONINGSVELD, R .
JOURNAL OF CHROMATOGRAPHY, 1984, 317 (DEC) :615-624
[10]   CHARACTERIZATION OF STYRENE-ACRYLONITRILE COPOLYMERS BY EXCLUSION CHROMATOGRAPHY AND TURBIDIMETRIC TITRATION OF THE FRACTIONS OBTAINED .1. TESTING MIXTURES [J].
GLOCKNER, G ;
ALBRECHT, V ;
FRANCUSKIEWICZ, F .
ANGEWANDTE MAKROMOLEKULARE CHEMIE, 1984, 127 (NOV) :153-169