DETERMINATION OF 6-MERCAPTOPURINE AND AZATHIOPRINE IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

被引:56
作者
DING, TL [1 ]
BENET, LZ [1 ]
机构
[1] UNIV CALIF SAN FRANCISCO, SCH PHARM, DEPT PHARMACOL, SAN FRANCISCO, CA 94143 USA
来源
JOURNAL OF CHROMATOGRAPHY | 1979年 / 163卷 / 03期
基金
美国国家卫生研究院;
关键词
D O I
10.1016/S0378-4347(00)81415-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Using 1-ml plasma samples, levels of 6-mercaptopurine (6MP) as low as 5 ng/ml and azathioprine (AZA) as low as 40 ng/ml can be detected using a high-performance liquid chromatography reversed-phase column procedure following extraction. Both compounds were stable in frozen plasma for seven weeks. AZA stability in blood was temperature dependent; the half-lives of AZA breakdown to 6MP at 37° were 28 and 46 min in blood drawn from two rhesus monkeys. Plasma levels of 6MP were measured in a rhesus monkey following 6MP (1.47 mg/kg) and AZA (3 mg/kg) intravenous administration. 6MP levels were also measured in three renal transplant patients on daily 50- and 100-mg AZA doses. Peak levels (45-75 ng/ml) were reached within an hour and 6MP levels were detected for up to 7 h. © 1979.
引用
收藏
页码:281 / 288
页数:8