ONLINE ALUMINUM PRECONCENTRATION ON CHELATING RESIN AND ITS FIA SPECTROFLUOROMETRIC DETERMINATION IN FOODS AND DIALYSIS CONCENTRATES

被引:31
作者
FERNANDEZ, P [1 ]
CONDE, CP [1 ]
GUTIERREZ, A [1 ]
CAMARA, C [1 ]
机构
[1] UNIV COMPLUTENSE MADRID,FAC CIENCIAS QUIM,DEPT QUIM ANALIT,E-28040 MADRID,SPAIN
关键词
D O I
10.1016/0039-9140(91)80285-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new, sensitive and rapid spectrofluorimetric flow-injection method, is presented for the determination of trace levels of aluminium based on the formation of a fluorescent complex between aluminium and 5,7-dibromo-8-quinolinol (DBQ), and its extraction into diethylether (lambda(exc) = 400 nm, lambda(em) = 525 nm). Experimental conditions such as pH, reagent concentration, flow-rates, sample volume, extraction coil length, etc., have been optimized for on-line and batch procedures. The detection limits are 1 ppb and 0.3 ppb for batch and on-line systems respectively. The coefficient of variation is 3.0% at the 4 ppb level for the FIA system. To remove interferences and to preconcentrate aluminium, a chelating resin microcolumn which was able to selectively complex Al(III) and was obtained by immobilizing Chromotrope 2B on AG1-X8 ion-exchange resin, was incorporated into the FIA system. The proposed method was successfully applied to determine aluminium in tap water, food samples and dialysis solutions.
引用
收藏
页码:1387 / 1392
页数:6
相关论文
共 12 条
[1]   FLOW-INJECTION AND LIQUID-CHROMATOGRAPHIC DETERMINATION OF ALUMINUM BASED ON ITS FLUORIMETRIC REACTION WITH 8-HYDROXYQUINOLINE-5-SULFONIC ACID IN A MICELLAR MEDIUM [J].
ALONSO, JIG ;
GARCIA, AL ;
SANZMEDEL, A ;
GONZALEZ, EB ;
EBDON, L ;
JONES, P .
ANALYTICA CHIMICA ACTA, 1989, 225 (02) :339-350
[2]   EVALUATION OF THE LVOV PLATFORM AND MATRIX MODIFICATION FOR THE DETERMINATION OF ALUMINUM IN SERUM [J].
BETTINELLI, M ;
BARONI, U ;
FONTANA, F ;
POISETTI, P .
ANALYST, 1985, 110 (01) :19-22
[4]   MINERALIZATION PROCEDURE FOR USE WITH THE FLUOROMETRIC-DETERMINATION OF ZINC IN BIOLOGICAL SAMPLES [J].
FERNANDEZ, P ;
CONDE, CP ;
GUTIERREZ, AM ;
CAMARA, C .
TALANTA, 1989, 36 (09) :960-962
[5]   FLUORIMETRIC DETERMINATION OF ALUMINUM WITH MORIN AFTER EXTRACTION WITH ISOBUTYL METHYL KETONE .1. FLUORESCENCE OF THE ALUMINUM - MORIN COMPLEX IN AN ISOBUTYL METHYL KETONE - ETHANOL - WATER-SYSTEM [J].
HERNANDEZ, FH ;
ESCRICHE, JM .
ANALYST, 1984, 109 (12) :1585-1588
[6]   TRACE-METAL ENRICHMENT BY AUTOMATED ONLINE COLUMN PRECONCENTRATION FOR FLOW-INJECTION ATOMIC-ABSORPTION SPECTROMETRY [J].
HIRATA, S ;
HONDA, K ;
KUMAMARU, T .
ANALYTICA CHIMICA ACTA, 1989, 221 (01) :65-76
[7]  
PEREIRO MR, 1990, J ANAL ATOM SPECTROM, V5, P15
[8]  
PESAVENTO M, 1982, ANN CHIM-ROME, V72, P217
[9]   SEPARATION OF TRACE AMOUNTS OF ALUMINUM ON A STRONG ANION-EXCHANGE RESIN LOADED WITH A SULFONATED AZO DYE [J].
PESAVENTO, M ;
PROFUMO, A ;
RIOLO, C ;
SOLDI, T .
ANALYST, 1989, 114 (05) :623-626
[10]   METAL CHELATE FLUORESCENCE ENHANCEMENT IN MICELLAR MEDIA - MECHANISMS OF SURFACTANT ACTION [J].
SANZMEDEL, A ;
DELACAMPA, RF ;
ALONSO, JIG .
ANALYST, 1987, 112 (04) :493-497