1ST DERIVATIVE OF RIGHT VENTRICULAR PRESSURE, DP DT, AS A SENSOR FOR A RATE ADAPTIVE VVI PACEMAKER - INITIAL EXPERIENCE

被引:14
作者
OVSYSHCHER, I
GUETTA, V
BONDY, C
PORATH, A
机构
[1] Soroka Medical Center, Beersheva
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1992年 / 15卷 / 02期
关键词
RIGHT VENTRICULAR DP DT; RATE ADAPTIVE PACEMAKER; CLOSED LOOP;
D O I
10.1111/j.1540-8159.1992.tb03065.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Ten patients underwent implantation of a rate adaptive ventricular pacing system with a new pulse generator and lead. The unipolar lead has a steroid eluting tip and a pressure sensor. The first derivative of the signal from this sensor, dP/dt, is determined and the pacemaker rate is varied in response to changes in the right ventricular dP/dt(MAX). During implantation, dP/dt values were in the range of 180-720 mm Hg/sec. The autothreshold for pacing at 2.5 V remained unchanged 1 month after implantation (0.065 +/- 0.045 msec, range 0.05-2.00 msec) and only slightly increased after 3 months (0.075 +/- 0.045 msec, range 0.05-2.00 msec). A significant correlation existed between the dP/dt measured during implantation and the right ventricular pressure measured by telemetry at follow-up visits (r = 0.93, P = 0.0001). Initial pacemaker programming was performed on the second day after implantation following a short walk and was adjusted subsequent to follow-up visits according to the patient's subjective assessment and in accordance with the results of exercise tests and Holter monitoring, Exercise and Holter tests did not significantly change initial programming. There was a significant correlation between right ventricular systolic pressure and the rate response setting (r = -0.66, P < 0.05). During dP/dt pacing, all patients felt well, and eight of these reported an improvement compared to nonrate adaptive pacing. The heart rate response to effort and recovery was appropriate. It was concluded that: (1) right ventricular dP/dt is a suitable parameter for controlling the pacing rate; (2) appropriate programming of the dP/dt pacemaker results in a suitable heart rate response to exercise and recovery.
引用
收藏
页码:211 / 218
页数:8
相关论文
共 19 条
[1]  
BENNETT TD, 1985, J AM COLL CARDIOL, V5, P393
[2]  
BENNETT TD, 1985, CARDIAC PACING ELECT, P577
[3]   INOTROPIC CHANGES IN LEFT VENTRICLE - EFFECT OF CHANGES IN HEART RATE, AORTIC PRESSURE AND END-DIASTOLIC PRESSURE [J].
FURNIVAL, CM ;
LINDEN, RJ ;
SNOW, HM .
JOURNAL OF PHYSIOLOGY-LONDON, 1970, 211 (02) :359-&
[4]   STUDIES ON FIRST DERIVATIVE OF VENTRICULAR PRESSURE PULSE IN MAN [J].
GLEASON, WL ;
BRAUNWALD, E .
JOURNAL OF CLINICAL INVESTIGATION, 1962, 41 (01) :80-&
[5]  
GUETTA V, 1990, PACE, V13, P509
[6]   METABOLIC EQUIVALENTS (METS) IN EXERCISE TESTING, EXERCISE PRESCRIPTION, AND EVALUATION OF FUNCTIONAL-CAPACITY [J].
JETTE, M ;
SIDNEY, K ;
BLUMCHEN, G .
CLINICAL CARDIOLOGY, 1990, 13 (08) :555-565
[7]   THE 6-MINUTE WALK - AN ADEQUATE EXERCISE TEST FOR PACEMAKER PATIENTS [J].
LANGENFELD, H ;
SCHNEIDER, B ;
GRIMM, W ;
BEER, M ;
KNOCHE, M ;
RIEGGER, G ;
KOCHSIEK, K .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1990, 13 (12) :1761-1765
[8]  
OVSYSHCHER I, 1991, PACE, V14, P733
[9]  
OVSYSHCHER I, 1990, PACE, V13, P515
[10]  
PARSONNET V, 1989, HEART DISEASE, P97