DOPPLER CARDIAC-OUTPUT AND LEFT-VENTRICULAR PERFORMANCE AFTER CARDIAC-SURGERY - PULSED DOPPLER ASCENDING AORTA AND PULMONARY BLOOD FLOWS AND LEFT-VENTRICULAR FUNCTION USING IMPLANTED MICROPROBES

被引:11
作者
FRATACCI, MD
PAYEN, D
BELOUCIF, S
LABORDE, F
机构
[1] LARIBOISIERE UNIV HOSP,DEPT ANESTHESIOL & INTENS CARE,PARIS,FRANCE
[2] LARIBOISIERE UNIV HOSP,CARDIOTHORAC SURG UNIT,PARIS,FRANCE
关键词
D O I
10.1378/chest.102.2.380
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
We have developed novel implantable Doppler microprobes to monitor beat-by-beat stroke volume and cardiac output (CO) after cardiac surgery. in 11 adults undergoing either coronary artery bypass grafting (n = 6) or valve replacement (n = 5), Doppler microprobes were implanted on the ascending aorta or the main pulmonary artery to measure aortic blood flow (ABF) or pulmonary artery blood flow (PBF). The diameters of both vessels were determined before surgery using two-dimensional echocardiography. Stroke volume was obtained from velocity tracings measured by a 4-MHz zero-crossing pulsed Doppler flowmeter. Simultaneous measurements of Doppler and thermodilution CO (TDCO) were compared. We found the following: ABF = 1.03 TDCO-0.22 L/min (r = 0.89); while PBF = 0.69 TDCO-1.24 L/min (r = 0.75). Furthermore, peak flow velocity and maximum acceleration of blood in the ascending aorta were measured after inotropic stimulation with dobutamine; both values increased significantly from control values (25.2 +/- 6.1 percent and 44.6 +/- 8.6 percent, respectively, at 7.5-mu-g/kg/min). We conclude that implanted aortic Doppler microprobes provide a sensitive and reliable method to measure aortic blood flow velocity after surgery and then allow monitoring of stroke volume and CO and analysis of left ventricular function after cardiac surgery.
引用
收藏
页码:380 / 386
页数:7
相关论文
共 31 条
  • [1] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [2] PULSED DOPPLER ULTRASOUND COMPARED WITH THERMODILUTION FOR MONITORING CARDIAC-OUTPUT RESPONSES TO CHANGING LEFT-VENTRICULAR FUNCTION
    BOJANOWSKI, LMR
    TIMMIS, AD
    NAJM, YC
    GOSLING, RG
    [J]. CARDIOVASCULAR RESEARCH, 1987, 21 (04) : 260 - 268
  • [3] THE USE OF DOPPLER FLOW VELOCITY-MEASUREMENT TO ASSESS THE HEMODYNAMIC-RESPONSE TO VASODILATORS IN PATIENTS WITH HEART-FAILURE
    ELKAYAM, U
    GARDIN, JM
    BERKLEY, R
    HUGHES, CA
    HENRY, WL
    [J]. CIRCULATION, 1983, 67 (02) : 377 - 383
  • [4] MEDICAL THERAPY OF ACUTE MYOCARDIAL-INFARCTION BY APPLICATION OF HEMODYNAMIC SUBSETS .1.
    FORRESTER, JS
    DIAMOND, G
    CHATTERJEE, K
    SWAN, HJC
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1976, 295 (24) : 1356 - 1362
  • [5] FRANCIS GS, 1975, BRIT HEART J, V37, P376
  • [6] EVALUATION OF BLOOD-FLOW VELOCITY IN THE ASCENDING AORTA AND MAIN PULMONARY-ARTERY OF NORMAL SUBJECTS BY DOPPLER ECHOCARDIOGRAPHY
    GARDIN, JM
    BURN, CS
    CHILDS, WJ
    HENRY, WL
    [J]. AMERICAN HEART JOURNAL, 1984, 107 (02) : 310 - 319
  • [7] GISVOLD SE, 1982, CARDIOVASC RES, V16, P26, DOI 10.1093/cvr/16.1.26
  • [8] GOLDBERG SJ, 1985, DOPPLER ECHOCARDIOGR, P74
  • [9] RELATION BETWEEN PRESSURE AND DIAMETER IN ASCENDING AORTA OF MAN
    GREENFIELD, JC
    PATEL, DJ
    [J]. CIRCULATION RESEARCH, 1962, 10 (05) : 778 - +
  • [10] VELOCITY PROFILE IN THE MAIN PULMONARY-ARTERY IN A CANINE MODEL
    HENRY, GW
    JOHNSON, TA
    FERREIRO, JI
    HSIAO, HS
    LUCAS, CL
    KEAGY, BA
    LORES, ME
    WILCOX, BR
    [J]. CARDIOVASCULAR RESEARCH, 1984, 18 (10) : 620 - 625