MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW IN THE DOG USING ULTRAFAST COMPUTED-TOMOGRAPHY - EXPERIMENTAL VALIDATION

被引:65
作者
GOBBEL, GT
CANN, CE
IWAMOTO, HS
FIKE, JR
机构
[1] UNIV CALIF SAN FRANCISCO,SCH MED,BRAIN TUMOR RES CTR,DEPT NEUROL SURG,BOX 0520,HSW 783,SAN FRANCISCO,CA 94143
[2] UNIV CALIF SAN FRANCISCO,SCH MED,DEPT RADIAT ONCOL,SAN FRANCISCO,CA 94143
[3] UNIV CALIF SAN FRANCISCO,SCH MED,DEPT RADIOL,SAN FRANCISCO,CA 94143
[4] UNIV CALIF SAN FRANCISCO,SCH MED,CARDIOVASC RES CTR,SAN FRANCISCO,CA 94143
[5] UNIV CALIF SAN FRANCISCO,SCH MED,GRAD GRP BIOPHYS,SAN FRANCISCO,CA 94143
关键词
CEREBRAL BLOOD FLOW; INDICATOR DILUTION TECHNIQUES; TOMOGRAPHY; X-RAY COMPUTED; DOGS;
D O I
10.1161/01.STR.22.6.772
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The applicability, feasibility, reproducibility, and accuracy of the method of measuring regional cerebral blood flow using ultrafast computed tomography were evaluated in 25 dogs under varying physiological and pathophysiological conditions. Regional cerebral blood flow values were 75.6 +/- 29.4 ml/100 g/min (mean +/- standard deviation) for the hemisphere, 68.4 +/- 28.2 ml/100 g/min for the basal ganglia, 41.2 +/- 15.0 ml/100 g/min for the internal capsule, and 80.8 +/- 37.2 ml/100 g/min for the neocortex. Measurements made 10 minutes apart were significantly (p < 0.05) correlated. Simultaneous measurements of regional cerebral blood flow by the microsphere and ultrafast computed tomography methods showed a significant (p < 0.05) correlation for the hemisphere (r = 0.95), basal ganglia (r = 0.95), and neocortex (r = 0.94) but not for the internal capsule (r = 0.51). Microsphere and ultrafast computed tomography regional cerebral blood flow values were also in agreement in radiation-damaged brain with appreciable blood-brain barrier breakdown, and the two methods demonstrated similar responsiveness of regional cerebral blood flow to alterations in arterial carbon dioxide tension. The accuracy and sensitivity of the ultrafast computed tomography technique suggests that it affords a useful new tool for studying normal and abnormal regional cerebral blood flow.
引用
收藏
页码:772 / 779
页数:8
相关论文
共 25 条
[1]   EVALUATION OF REGIONAL CEREBRAL-CIRCULATION BASED ON ABSOLUTE MEAN TRANSIT TIMES IN RADIONUCLIDE CEREBRAL-ANGIOGRAPHY [J].
CARLSEN, O ;
HEDEGAARD, O .
PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (11) :1457-1467
[2]   CEREBRAL BLOOD-FLOW IN HUMANS FOLLOWING RESUSCITATION FROM CARDIAC-ARREST [J].
COHAN, SL ;
MUN, SK ;
PETITE, J ;
CORREIA, J ;
DASILVA, AT ;
WALDHORN, RE .
STROKE, 1989, 20 (06) :761-765
[3]  
DEVORE J, 1987, PROBABILITY STATISTI, P391
[4]   EVALUATION OF BRAIN CIRCULATION BY RAPID ROTATIONAL COMPUTED-TOMOGRAPHY [J].
DOBBEN, GD ;
VALVASSORI, GE ;
MAFEE, MF ;
BERNINGER, WH .
RADIOLOGY, 1979, 133 (01) :105-111
[5]   RELATIVE ERROR AND VARIABILITY IN BLOOD-FLOW MEASUREMENTS WITH RADIOLABELED MICROSPHERES [J].
DOLE, WP ;
JACKSON, DL ;
ROSENBLATT, JI ;
THOMPSON, WL .
AMERICAN JOURNAL OF PHYSIOLOGY, 1982, 243 (03) :H371-H378
[6]   QUANTITATIVE-EVALUATION OF THE CANINE BRAIN USING COMPUTED-TOMOGRAPHY [J].
FIKE, JR ;
CANN, CE ;
BERNINGER, WH .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1982, 6 (02) :325-333
[7]   COMPUTED-TOMOGRAPHY ANALYSIS OF THE CANINE BRAIN - EFFECTS OF HEMIBRAIN X-IRRADIATION [J].
FIKE, JR ;
CANN, CE ;
DAVIS, RL ;
BORCICH, JK ;
PHILLIPS, TL ;
RUSSELL, LB .
RADIATION RESEARCH, 1984, 99 (02) :294-310
[8]   THE DISTRIBUTION OF RED CELLS AND PLASMA IN LARGE AND MINUTE VESSELS OF THE NORMAL DOG, DETERMINED BY RADIOACTIVE ISOTOPES OF IRON AND IODINE [J].
GIBSON, JG ;
SELIGMAN, AM ;
PEACOCK, WC ;
AUB, JC ;
FINE, J ;
EVANS, RD .
JOURNAL OF CLINICAL INVESTIGATION, 1946, 25 (06) :848-857
[9]  
GOBBEL GT, 1990, STROKE, V22, P768