IN-SITU CURE MONITORING OF EPOXY-RESINS USING FIBEROPTIC RAMAN-SPECTROSCOPY

被引:81
作者
LYON, RE [1 ]
CHIKE, KE [1 ]
ANGEL, SM [1 ]
机构
[1] UNIV S CAROLINA,DEPT CHEM,COLUMBIA,SC 29208
关键词
D O I
10.1002/app.1994.070531310
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Fiber-optic Raman spectroscopy was used to monitor the curing of epoxy resins in situ for eventual application to polymer composite processing. A 200-mu m diameter quartz fiberoptic sensor immersed in liquid resin was used to obtain Raman spectra for a concentration series of diglicidyl ether of bisphenol-A in its own reaction product with diethylamine using an 820 nm continuous-wave diode laser excitation. A Raman peak at 1240 cm(-1) was assigned to a vibrational mode of the oxirane (epoxide) ring and its normalized intensity was found to be linearly related to the concentration of epoxide groups in the resin mixtures. Raman peaks at 1112 and 1186 cm(-1) associated with phenyl and gen-dimethyl resin backbone vibrations, respectively, did not change in intensity due to the curing reaction and were used as internal references to correct the Raman spectra for intensity changes due to density fluctuations and instrumental variations during the experiments. Fiber-optic Raman spectroscopy was used to monitor the extent of reaction in situ for the room-temperature cure of phenyl glicidyl ether with diethylamine. The extent of reaction of the epoxide groups calculated from the Raman spectra were in excellent agreement with kinetic data from Fourier transform near-infrared absorbance measurements made under the same conditions. (C) 1994 John Wiley and Sons, Inc.
引用
收藏
页码:1805 / 1812
页数:8
相关论文
共 28 条
[1]   NEAR-INFRARED RAMAN-SPECTROSCOPY OF LIQUIDS AND SOLIDS WITH A FIBEROPTIC SAMPLER, DIODE-LASER, AND CCD DETECTOR [J].
ALLRED, CD ;
MCCREERY, RL .
APPLIED SPECTROSCOPY, 1990, 44 (07) :1229-1231
[2]  
ANGEL SM, 1991, P SOC PHOTO-OPT INS, V1435, P72, DOI 10.1117/12.44232
[3]   RAMAN-SPECTROSCOPY OVER OPTICAL FIBERS WITH THE USE OF A NEAR-IR FT SPECTROMETER [J].
ARCHIBALD, DD ;
LIN, LT ;
HONIGS, DE .
APPLIED SPECTROSCOPY, 1988, 42 (08) :1558-1563
[4]  
AUST JF, 1993, MAR P PITTSB C AN CH
[5]   RAMAN AND NEAR-INFRARED STUDIES OF AN EPOXY-RESIN [J].
CHIKE, KE ;
MYRICK, ML ;
LYON, RE ;
ANGEL, SM .
APPLIED SPECTROSCOPY, 1993, 47 (10) :1631-1635
[6]  
CIRISCIOLI PR, 1989, SAMPE J, V25, P35
[7]  
DANNENBERG H, 1963, SPE TRANS, V3, P78
[8]  
DAY DR, 1988, NOV ASME C ADV COMP, P1
[9]  
DRUY MA, 1989, P SOC PHOTO-OPT INS, V1170, P150
[10]   DETERMINATION OF TERMINAL EPOXIDES BY NEAR-INFRARED SPECTROPHOTOMETRY [J].
GODDU, RF ;
DELKER, DA .
ANALYTICAL CHEMISTRY, 1958, 30 (12) :2013-2016