NEAR-INFRARED SPECTROSCOPIC DETERMINATION OF SERUM TOTAL PROTEINS, ALBUMIN, GLOBULINS, AND UREA

被引:59
作者
HALL, JW
POLLARD, A
机构
[1] NIR SYST INC,TORONTO M3J 1P3,ON,CANADA
[2] UNIV TORONTO,DEPT CLIN BIOCHEM,TORONTO M5G 1L5,ONTARIO,CANADA
关键词
NEAR-INFRARED SPECTROSCOPY; SERUM ANALYSIS; CHEMOMETRICS; NONDESTRUCTIVE ANALYSIS;
D O I
10.1016/0009-9120(93)80013-K
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
We have determined total protein, albumin, globulins, and urea in unmodified human serum using near-infrared (NIR) spectroscopy. The distinctive NIR spectrum of the individual protein fractions allowed unique spectroscopic models to be derived for each fraction using multiple linear least-squares regression (MLR). A more sophisticated partial least-squares (PLS) regression analysis was necessary to fully extract the relevant spectral information for urea. The serum protein data sets consisted of 235 calibration samples and 85 prediction samples. The total protein calibration yielded a multiple correlation coefficient (R) of 0.986 and a standard error of calibration (SEC) of 1.7 g/L. For the validation data set, a correlation coefficient (r) of 0.985 and standard error of prediction (SEP) of 1.7 g/L were obtained. For albumin, the values were R = 0.982 and SEC = 1.2 g/L for calibration and r = 0.984 and SEP = 1.1 g/L for prediction. Calibration results for globulins were R = 0.916 and SEC = 2.1 g/L: validation results were r = 0.885 and SEP = 2.2 g/L. The sum of the separately estimated albumin and globulin fractions agreed well with the total protein estimate. For urea, the calibration model (n = 422) provided an R = 0.994 and SEC = 0.7 mmol/L and the validation results (n = 208) were r = 0.993 and SEP = 0.8 mmol/L. The within-day and between-day precision values (CVs) were respectively, 1.2 and 1.3% for total protein, 1.7 and 1.1% for albumin, 1.5 and 1.30/. for globulins, and 8.3 and 5.5% for urea.
引用
收藏
页码:483 / 490
页数:8
相关论文
共 12 条
  • [1] DETERMINATION OF PHYSIOLOGICAL LEVELS OF GLUCOSE IN AN AQUEOUS MATRIX WITH DIGITALLY FILTERED FOURIER-TRANSFORM NEAR-INFRARED SPECTRA
    ARNOLD, MA
    SMALL, GW
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (14) : 1457 - 1464
  • [2] DRENNEN JK, 1991, SPECTROSCOPY, V6, P28
  • [3] REAGENTLESS NEAR-INFRARED DETERMINATION OF GLUCOSE IN WHOLE-BLOOD USING MULTIVARIATE CALIBRATION
    HAALAND, DM
    ROBINSON, MR
    KOEPP, GW
    THOMAS, EV
    EATON, RP
    [J]. APPLIED SPECTROSCOPY, 1992, 46 (10) : 1575 - 1578
  • [4] HALL JW, 1992, CLIN CHEM, V38, P1623
  • [5] JENSEN R, 1986, B SOC PHARM BORDEAUX, V125, P43
  • [6] Martens H, 1989, MULTIVARIATE CALIBRA
  • [7] DETERMINATION OF SERUM-CHOLESTEROL BY NEAR-INFRARED REFLECTANCE SPECTROMETRY
    PEUCHANT, E
    SALLES, C
    JENSEN, R
    [J]. ANALYTICAL CHEMISTRY, 1987, 59 (14) : 1816 - 1819
  • [8] COMPARISON OF MULTIVARIATE CALIBRATION METHODS FOR QUANTITATIVE SPECTRAL-ANALYSIS
    THOMAS, EV
    HAALAND, DM
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (10) : 1091 - 1099
  • [9] VANTOORENENBERGEN AW, 1988, J CLIN CHEM CLIN BIO, V26, P209
  • [10] 1992, MP217 EASTM KOD CO P