An orthodontic measurement, and simulation system (OMSS) is introduced. The major component of the system consists of two force-moment sensors capable of measuring forces and moments in all three planes of space simultaneously. The two sensors are mounted on motor-driven positioning tables with full three-dimensional mobility. All mechanical components are built in a temperature-controlled chamber. A control programme executed by a personal computer performs various types of measurement which can be classified as absolute measurements (e.g. force-deflection diagrams) and simulations of orthodontic tooth movement. By using the OMSS any orthodontic problem at the level of a two-tooth model can be analysed statically and dynamically. Besides other applications, the study evaluates three mechanical systems available for uprighting molars, namely a straight wire, a conventional uprighting spring, and a modified Burstone uprighting spring. It was found that the force systems produced by the straight wire and by the conventional uprighting spring showed a severe extrusive force component which may lead to occlusal trauma. The uprighting performance of the straight wire was inadequate. The conventional uprighting spring produced a large uprighting moment (17.8 Nmm), but also a strong lingual tipping moment (1.5 Nmm). The modified Burstone loop showed the best static and dynamic performance. It produced a force system with substantial uprighting moments in both the sagittal (11.6 Nmm) and frontal plane (4.2 Nmm). A slight intrusive force (0.09 N) might prevent the development of occlusal trauma during treatment. However, concern should be addressed to the fact that intra-oral adjustment of this uprighting spring is difficult because of its high susceptibility to minor modifications of its geometry.
引用
收藏
页码:169 / 178
页数:10
相关论文
共 21 条
[1]  
Bourauel C., Drescher D., Thier M., Kraft-Momenten-Aufnehmer fur die Kieferorthopadie, Feinwerktechnik, 98, pp. 419-422, (1990)
[2]  
Burstone C.J., Koenig H.A., Force systems from an ideal arch, American Journal of Orthodontics, 65, pp. 270-289, (1974)
[3]  
Burstone C.J., Pryputniewicz R.J., Holographic determination of centers of rotation produced by orthodontic forces, American Journal of Orthodontics, 77, pp. 396-409, (1980)
[4]  
Burstone C.J., Solonche J., Erson N.D., Papir D.J., A strain gauge transducer model for evaluation of clinicalappliances in two-tooth segment, American Journal ofOrthodontics, 69, (1976)
[5]  
Christiansen R.L., Burstone C.J., Centers of rotation within the periodontal space, American Journal of Ortho-Dontics, 55, pp. 353-369, (1969)
[6]  
Diedrich P., Die Aufrichtung gekippter Molaren als praprothetische und parodontitisprophylaktische MaB-nahme, Deutsche Zahnarztliche Zeitschrift, 41, pp. 159-163, (1986)
[7]  
Bourauel Thier D.C.M., Konstruktion eines Sechs-Komponenten-Kraft-Momenten-Sensors fur dieMikrorobotik, Sensor-Report, (1990)
[8]  
Fritz H., Wurll P., Tactile force-torque sensor for performing control tasks in robotics, Siemens Forschungs-Und Entwicklungs-Berichte, 15, pp. 120-123, (1986)
[9]  
Gjessing P., Biomechanical design and clinical evaluation of a new canine-retraction spring, American Journal of Orthodontics, 87, pp. 353-362, (1985)
[10]  
Helms D., Entwicklung eines Sechs-Komponenten Kraft-Momenten-Aufnehmers, Feinwerktechnik &MeBtechnik, 85, pp. 75-81, (1977)