IMPROVED DOSE HOMOGENEITY IN ELECTRON ARC THERAPY ACHIEVED BY A MULTIPLE-ENERGY TECHNIQUE

被引:17
作者
LEAVITT, DD
STEWART, JR
EARLEY, L
机构
[1] Division of Radiation Oncology, Department of Radiology, University of Utah dical Center, Salt Lake City
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1990年 / 19卷 / 01期
关键词
Electron arc therapy; Optimization;
D O I
10.1016/0360-3016(90)90149-E
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Improved dose homogeneity throughout the treatment volume defined for electron arc therapy is achieved through superposition of multiple arcs of different electron energy to the same treatment surface. The relative weights for each arc segment and energy are determined by computer optimization which minimizes the variation in radial depth dose across the treatment volume. In depth dose across the treatment volume. In addition to the standard electron beam of 6 MeV, 9 MeV, 12 MeV, 16 MeV and 20 MeV, a new electron arc field is created by adding bolus to the treatment surface during an additional pass using 6 MeV electrons. This modified field, having maximum dose on the patient surface and a reduced range, supplement the dose delivered by the standard electron arc fields in the buildup region. Through use of this multiple-energy technique, depending on clinical indications, electron arc therapy can be planned and delivered to allow either skin sparing or a uniform dose from the patient's surface to the desired treatment depth. © 1990.
引用
收藏
页码:159 / 165
页数:7
相关论文
共 9 条
[1]   PARTIAL BOLUSSING TO IMPROVE THE DEPTH DOSES IN THE SURFACE REGION OF LOW-ENERGY ELECTRON-BEAMS [J].
GALBRAITH, DM ;
RAWLINSON, JA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1984, 10 (02) :313-317
[2]  
JACHINOWSKI J, 1989, 6TH P VAR EUR US M
[3]   ELECTRON ARC THERAPY - PHYSICAL MEASUREMENT AND TREATMENT PLANNING TECHNIQUES [J].
LEAVITT, DD ;
PEACOCK, LM ;
GIBBS, FA ;
STEWART, JR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1985, 11 (05) :987-999
[4]   ELECTRON ARC THERAPY - DESIGN, IMPLEMENTATION AND EVALUATION OF A DYNAMIC MULTI-VANE COLLIMATOR SYSTEM [J].
LEAVITT, DD ;
STEWART, JR ;
MOELLER, JH ;
LEE, WL ;
TAKACH, GA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 17 (05) :1089-1094
[5]   OPTIMIZATION OF ELECTRON ARC THERAPY DOSES BY MULTI-VANE COLLIMATOR CONTROL [J].
LEAVITT, DD ;
STEWART, JR ;
MOELLER, JH ;
EARLEY, L .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 16 (02) :489-496
[6]  
LEAVITT DD, 1978, MED PHYS, V5, P347
[7]   ELECTRON ARC THERAPY - CHEST WALL IRRADIATION OF BREAST-CANCER PATIENTS [J].
MCNEELY, LK ;
JACOBSON, GM ;
LEAVITT, DD ;
STEWART, JR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 14 (06) :1287-1294
[8]   ELECTRON ARC THERAPY - CLINICAL-EXPERIENCE WITH CHEST WALL IRRADIATION [J].
PEACOCK, LM ;
LEAVITT, DD ;
GIBBS, FA ;
STEWART, JR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1984, 10 (11) :2149-2153
[9]   ELECTRON-BEAM ARC THERAPY USING A HIGH-ENERGY BETATRON [J].
RUEGSEGGER, DR ;
LERUDE, SD ;
LYLE, D .
RADIOLOGY, 1979, 133 (02) :483-489