TC-99M-SESTAMIBI FOR PLANAR MYOCARDIAL PERFUSION IMAGING - NOT AS IDEAL AS THE PHYSICAL-PROPERTIES

被引:6
作者
VERZIJLBERGEN, JF
CRAMER, MJ
NIEMEYER, MG
ASCOOP, CAPL
VANDERWALL, EE
PAUWELS, EKJ
机构
[1] Departments of Nuclear Medicine, Leiden
[2] Departments of Cardiology, St Antonius Hospital, Nieuwegein, Leiden
[3] Department of Diagnostic Radiology, Division of Nuclear Medicine, Leiden
[4] Department of Cardiology, University Hospital, Leiden
关键词
D O I
10.1097/00006231-199105000-00002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
99Tcm-methoxyisobutyl isonitrile (Tc-SESTAMIBI) has recently been introduced as a new myocardial perfusion agent which exhibits ideal physical properties for imaging with the gamma camera. To assess the diagnostic accuracy of planar Tc-SESTAMIBI, myocardial perfusion imaging was performed in 60 consecutive patients at rest and during exercise. The results were compared with coronary angiographic findings, obtained within 3 months of the exercise test. Planar Tl-201 images were also performed on the same day and to the same level of stress as the Tc-SESTAMIBI exercise. Exact segmental agreement between Tc-SESTAMIBI and Tl-201 was 77%. Nineteen per cent of all 900 segments demonstrated ischaemia with Tc-SESTAMIBI and 20% with Tl-201. The overall sensitivity for detecting haemodynamically significant coronary artery disease with Tc-SESTAMIBI was 86% and specificity was 78%; with Tl-201 the values were 89 and 78%, respectively (differences not significant). Vessel-specific comparative detection rates revealed no statistical significant differences between both radiopharmaceuticals. Intra-observer variability for Tc-SESTAMIBI images was 12% and for Tl-201 it was 14%. Inter-observer variability for Tc-SESTAMIBI was 14% and for Tl-201 17%. Although the physical characteristics of Tc-SESTAMIBI allow crisp and clear high-count density imaging, no significant differences are found when planar images are compared with Tl-201 and are well within observer variabilities.
引用
收藏
页码:381 / 391
页数:11
相关论文
共 15 条
[1]  
Rozanski A., Berman S., The efficacy of cardiovascular nuclear medicine exercise studies, Sem Nucl Med, 17, pp. 104-120, (1987)
[2]  
Jones A.G., Abrams M.J., Davison A., Brodack J.W., Toothaker A.K., Et al., Biological studies of a new class of technetium complexes: The hexakis (alkylisonitrile) technetium (I) cations, Inf J Nucl Med Biol, 11, pp. 225-234, (1984)
[3]  
Okada R.D., Glover D., Gaffney T., Williams S., Myocardial kinetics of technetium-99m- hexakis-2-methoxy-2-methylpropyl-isonitrile, Circulation, 77, pp. 491-498, (1988)
[4]  
Kiat H., Maddahi J., Roy L.T., Van Train K., Friedman J., Et al., Comparison of technetium 99m methoxy-isobutyl isonitrile and thallium 201 for evaluation of coronary artery disease by planar and tomographic methods, Am Heart J, 117, pp. 1-11, (1989)
[5]  
Taillefer R., Dupras G., Spom V., Rigo P., Leveille J., Et al., Myocardial perfusion imaging with a new radiotracer technetium-99m-hexamibi (Methoxyisobutyl isonitrile): Comparison with thallium-201 imaging, Clin Nucl Med, 14, pp. 89-96, (1989)
[6]  
Wackers F., Berman D.S., Maddahi J., Watson D.D., Beller G.A., Et al., Technetium-99m hexakis 2-methoxy-isobutyl isonitrile: Human biodistribution, dosimetry, safety, and preliminary comparison to thallium-201 for myocardial perfusion imaging, J Nucl Med, 30, pp. 301-311, (1989)
[7]  
Maublant J.C., Gachon P., Moins N., Hexabrix (2-methoxyisobutyl-isonitrile) Technetium- 99m and Thallium-201 chloride: Uptake and release in cultured myocardial cells, J Nucl Med, 29, pp. 48-54, (1988)
[8]  
Li Q.S., Solot G., Frank T.L., Wagner H.N., Becker L.C., Myocardial redistribution of Technetium-99m-methoxy-isobutyl Isonitrile (SESTAMIBI), J Nucl Med, 31, pp. 1069-1076, (1990)
[9]  
Wilson R.A., Sullivan P.J., Okada R.D., Boucher C.A., Morris C., Pohost G.M., Strauss H.W., The effect of eating on thallium myocardial imaging, Chest, 89, pp. 195-198, (1986)
[10]  
Ascoop C., Klein B., Neimeyer M., Van Oudheusden D., Rijneke R., Et al., On the clinical value of thallium-201 washout analysis in the detection of multiple jeopardized myocardial regions, Int J Cardiol, 11, pp. 305-316, (1986)