FOURIER-TRANSFORM MASS-SPECTROMETRIC DETECTION OF SUSPENDED TRAPPING MEASUREMENTS WITH A VARIABLE LENGTH EXTERNAL ION RESERVOIR

被引:7
作者
HOFSTADLER, SA [1 ]
LAUDE, DA [1 ]
机构
[1] UNIV TEXAS,DEPT CHEM,AUSTIN,TX 78712
来源
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES | 1990年 / 97卷 / 02期
关键词
D O I
10.1016/0168-1176(90)85056-8
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
The effect of Fourier transform mass spectrometry (FTMS) suspended trapping events on the evolution of ion cloud spatial and kinetic energy distributions during ion flight is evaluated by FTMS. A probe-mounted electrode permits the initial formation of ions in variable length reservoirs adjacent to the trapped ion cells to facilitate these measurements. Several experiments are presented to demonstrate the versatility of the apparatus. For example, FTMS-time-of-flight (TOF) detection of ion flight from the trapped ion cell is used to investigate collisional relaxation. In another experiment, the kinetic energy of FTMS-detected ions entering the trapped ion cell following a suspension of trapping potentials is found by time-of-flight analysis to be less than 0.1 eV, independent of initial trap potential. The reservoir is used to directly observe the trapping oscillations of ions in elongated wells up to 43 cm in length. The trapping period is found to vary proportionally with cell length, in contrast to present models for the motion. Finally, the utility of suspended trapping for alleviating space charge effects is demonstrated. © 1990.
引用
收藏
页码:151 / 164
页数:14
相关论文
共 15 条
[1]   METAL CLUSTER ION-CYCLOTRON RESONANCE - COMBINING SUPERSONIC METAL CLUSTER BEAM TECHNOLOGY WITH FT-ICR [J].
ALFORD, JM ;
WILLIAMS, PE ;
TREVOR, DJ ;
SMALLEY, RE .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1986, 72 (1-2) :33-51
[2]   FREQUENCY-SWEEP FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE SPECTROSCOPY [J].
COMISARO.MB ;
MARSHALL, AG .
CHEMICAL PHYSICS LETTERS, 1974, 26 (04) :489-490
[3]  
Comisarow M. B., 1980, ADV MASS SPECTROM B, V8B, P1698
[4]   ERROR ESTIMATES FOR FINITE ZERO-FILLING IN FOURIER-TRANSFORM SPECTROMETRY [J].
COMISAROW, MB ;
MELKA, JD .
ANALYTICAL CHEMISTRY, 1979, 51 (13) :2198-2203
[5]   SELECTIVE-PHASE ION-CYCLOTRON RESONANCE SPECTROSCOPY [J].
COMISAROW, MB ;
MARSHALL, AG .
CANADIAN JOURNAL OF CHEMISTRY, 1974, 52 (10) :1997-1999
[6]   CUBIC TRAPPED-ION CELL FOR ION-CYCLOTRON RESONANCE [J].
COMISAROW, MB .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1981, 37 (02) :251-257
[7]   AN EXPERIMENTAL-STUDY OF ION MOTIONS IN A DOUBLE CELL FT/ICR INSTRUMENT [J].
GIANCASPRO, C ;
VERDUN, FR ;
MULLER, JF .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1986, 72 (1-2) :63-71
[8]   HIGH-RESOLUTION ION PARTITIONING TECHNIQUE BY PHASE-SPECIFIC ION EXCITATION FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE [J].
HANSON, CD ;
KERLEY, EL ;
RUSSELL, DH .
ANALYTICAL CHEMISTRY, 1989, 61 (01) :83-85
[9]  
HOGAN JD, 1989, ANAL CHEM, V61, P2422
[10]   AN ELONGATED TRAPPED-ION CELL FOR ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY WITH A SUPERCONDUCTING MAGNET [J].
HUNTER, RL ;
SHERMAN, MG ;
MCIVER, RT .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1983, 50 (03) :259-274