AUTOMATIC REDUCTION OF STIMULUS POLARIZATION ARTIFACT FOR ACCURATE EVALUATION OF VENTRICULAR EVOKED-RESPONSES

被引:24
作者
CURTIS, AB [1 ]
VANCE, F [1 ]
MILLER, K [1 ]
机构
[1] TELECTR PACING SYST,ENGLEWOOD,CO
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1991年 / 14卷 / 04期
关键词
PACEMAKERS; EVOKED POTENTIALS; POLARIZATION; PACEMAKER ARTIFACT;
D O I
10.1111/j.1540-8159.1991.tb02825.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The ventricular evoked response, the cardiac depolarization generated in response to a pacing stimulus, is potentially useful as a sensor for rate responsive pacing and automatic threshold tracking. It is necessary to minimize the polarization artifact that results from pacing in order to sense cardiac depolarizations from the same electrodes that pace the heart. To accomplish this, a triphasic stimulus waveform consisting of precharge, stimulus, and postcharge was used. An algorithm was developed that introduced pacing stimuli during the refractory period of sensed beats, when cardiac depolarization could not occur by definition and polarization artifact could be evaluated. Precharge duration was varied until the amplitude of the polarization artifact was small compared to the evoked response. In 18 patients with temporary electrode catheters, polarization artifact was reduced from 6.8 +/- 3.4 mV to 1.9 +/- 1.1 mV after balancing (P < 0.005). Initial precharge duration was 3200-mu-sec and the mean final precharge duration was 3551 +/- 516-mu-sec. In 14 patients with permanent bipolar pacing leads, polarization artifact was reduced from 3.2 +/- 3.5 mV to 0.7 +/- 0.6 mV (P < 0.025). Final precharge duration averaged 3440 +/- 310-mu-sec. Under a wide variety of pacing conditions, this algorithm simply and quickly reduces polarization artifact to a minimum to allow accurate analysis of evoked responses.
引用
收藏
页码:529 / 537
页数:9
相关论文
共 10 条
[1]   AUTODIAGNOSTIC PACEMAKER [J].
AUERBACH, AA ;
FURMAN, S .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1979, 2 (01) :58-68
[2]   MORPHOLOGY OF ENDOCARDIAL T-WAVES OF FUSION BEATS [J].
BOUTE, W ;
CALS, GLM ;
DENHEIJER, P ;
WITTKAMPF, FHM .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (11) :1693-1697
[3]   THE VENTRICULAR DEPOLARIZATION GRADIENT - EFFECTS OF EXERCISE, PACING RATE, EPINEPHRINE, AND INTRINSIC HEART-RATE CONTROL ON THE RIGHT VENTRICULAR EVOKED-RESPONSE [J].
CALLAGHAN, F ;
VOLLMANN, W ;
LIVINGSTON, A ;
BOVEJA, B ;
ABELS, D .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (07) :1115-1130
[4]   CHARACTERISTIC VARIATION IN EVOKED-POTENTIAL AMPLITUDE WITH CHANGES IN PACING STIMULUS STRENGTH [J].
CURTIS, AB ;
VANCE, F ;
MILLERSHIFRIN, K .
AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (04) :416-422
[5]   RAPID ASSESSMENT OF RATE AND ANTIARRHYTHMIC DRUG EFFECT ON THE MYOCARDIUM USING ASYMMETRIC BIPHASIC PULSE STIMULATION [J].
FURUKAWA, T ;
HERSCOVICI, H ;
DESAI, T ;
SAMPSELL, R ;
NOGAMI, A ;
MOROE, K ;
ROZANSKI, JJ ;
LISTER, JW .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (01) :52-64
[6]  
MUGICA J, 1973, CARDIAC PACING, P150
[7]  
Preston T A, 1974, Med Instrum, V8, P322
[8]  
PRESTON TA, 1973, CARDIAC PACING, P295
[9]  
RICKARDS AF, 1981, BRIT HEART J, V45, P56
[10]  
THALEN HJT, 1981, 2ND P EUR S CARD PAC, P1229