ACCURACY OF MULTIELEMENT ANALYSIS OF HUMAN TISSUE OBTAINED AT AUTOPSY USING INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY

被引:20
作者
LYON, TDB [1 ]
FELL, GS [1 ]
MCKAY, K [1 ]
SCOTT, RD [1 ]
机构
[1] SCOTTISH UNIV RES & REACTOR CTR,NATL ENGN LAB,E KILBRIDE G75 0QU,LANARK,SCOTLAND
关键词
INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY; MULTIELEMENT ANALYSIS; ACCURACY; AUTOPSY TISSUE; REFERENCE MATERIALS;
D O I
10.1039/ja9910600559
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The accuracy of inductively coupled plasma mass spectrometry (ICP-MS) for the multi-element analysis of human tissue has been assessed by analysis of National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 1577a Bovine Liver, International Atomic Energy (IAEA) Certified Reference Material (CRM) H 8 Kidney and IAEA CRM H 4 Animal Muscle for Al, Mg, Mn, Fe, Co, Zn, Cu, Mo, Rb, Sr and Cd. Twenty three out of 24 determinations agreed with certified values. An intercomparison was also made between ICP-MS and the well established technique of atomic absorption spectrometry (AAS) for Al, Mg, Mn, Fe, Cu, Zn and Cd in human tissue samples, which covered a much wider range of analyte concentrations than the reference materials. Drift in the ICP-MS instrument was studied for 3 h and all but the lighter elements Al and Mg were found to be acceptably controlled by an In internal standard. The equivalence of the ICP-MS and AAS data was compared using the usual statistics of correlation and regression. In addition, comparisons were made using the statistical analysis advocated by Bland and Altman. In spite of the problems found, ICP-MS is capable of accurate and rapid multi-element analysis of human autopsy tissue.
引用
收藏
页码:559 / 564
页数:6
相关论文
共 6 条
[1]   USE OF EXTERNAL CALIBRATION FOR THE DETERMINATION OF TRACE-METALS IN BIOLOGICAL-MATERIALS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
BEAUCHEMIN, D ;
MCLAREN, JW ;
BERMAN, SS .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (06) :775-780
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   ANALYSIS OF BIOLOGICAL REFERENCE MATERIALS, PREPARED BY MICROWAVE DISSOLUTION, USING INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
FRIEL, JK ;
SKINNER, CS ;
JACKSON, SE ;
LONGERICH, HP .
ANALYST, 1990, 115 (03) :269-273
[4]   DETERMINATION OF THORIUM AND URANIUM IN BIOLOGICAL SAMPLES BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY USING INTERNAL STANDARDIZATION [J].
IGARASHI, Y ;
KAWAMURA, H ;
SHIRAISHI, K ;
TAKAKU, Y .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (07) :571-576
[5]   EVALUATION OF INDUCTIVELY COUPLED ARGON PLASMA MASS-SPECTROMETRY (ICP-MS) FOR SIMULTANEOUS MULTI-ELEMENT TRACE ANALYSIS IN CLINICAL-CHEMISTRY [J].
LYON, TDB ;
FELL, GS ;
HUTTON, RC ;
EATON, AN .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (01) :265-271
[6]   DETERMINATION OF TRACE-ELEMENTS IN A MARINE REFERENCE MATERIAL OF LOBSTER HEPATOPANCREAS (TORT-1) USING INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
RIDOUT, PS ;
JONES, HR ;
WILLIAMS, JG .
ANALYST, 1988, 113 (09) :1383-1386