CRS RECEIVER AND STORAGE-SYSTEMS EVALUATION

被引:6
作者
CASTRO, M [1 ]
PRESA, JL [1 ]
DIAZ, J [1 ]
PEIRE, J [1 ]
BAKER, AF [1 ]
FAAS, SE [1 ]
RADOSEVICH, LG [1 ]
SKINROOD, AC [1 ]
机构
[1] SANDIA NATL LABS,DIV PROJECT ENGN 3,LIVERMORE,CA 94551
关键词
Solar Power Plants;
D O I
10.1016/0038-092X(91)90079-C
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This article describes a comparison and evaluation of the Solar One and CESA-I receiver and thermal storage systems. The evaluation is based on operating data from Solar One, the 10 MW(e) experimental solar central receiver plant located near Barstow, California, U.S.A., and CESA-I, the 1.2 MW(e) experimental solar central receiver plant located near Almeria, Spain. This study was sponsored by the U.S.-Spain Joint Committee for Scientific and Technological Cooperation. Significant differences exist in the design and operation of the receiver and thermal storage systems for the two experimental plants. An evaluation of their performance has increased our understanding of the plant design variables and provides useful information to improve the designs of future central receiver plants.
引用
收藏
页码:197 / 207
页数:11
相关论文
共 5 条
[1]  
BAKER AF, 1989, SAND898262 SAND NAT
[2]  
KUNTZ P, 1986, SAND868009 SAND NAT
[3]  
ORTIZ C, 1984, PERFORMANCE CESA 1 W
[4]  
RADOSEVICH LG, 1985, SAND858015 SAND NAT
[5]  
ROSA F, 1987, EVALUACION ALMACENAM