摘要
The values of acoustic and image texture parameters were estimated from liver scans of healthy subjects. The values were obtained after appropriate preprocessing of the radio frequency echograms by an on-line computerized system. The preprocessing comprised a correction for the Time Gain Compensation (TGC), the beam diffraction and the frequency dependent attenuation in the Region of Interest (ROI). The intra-and interindividual variability of the parameter values appeared to be of the same order of magnitude, but significantly larger than the variability assessed by measurements of a homogeneously scattering tissue mimicking phantom. Significant temporal effects were found for all the parameters, which consistently occurred during the morning. These results are discussed in relation to the circadian rhythm of the glycogen content and of the hepatic circulation. All the parameters appeared to be significantly correlated to age. The slope of the regression ranged from 3.6% per decade (attenuation coefficient) to 7.6% per decade (mean echolevel). A tentative explanation to these results is presented: the increased stiffness of hepatic vasculature with age.
引用
收藏
页码:857 / 867
页数:11
相关论文
共 50 条
[1]   INFLUENCE OF PATHOLOGICAL STATE ON THE ACOUSTIC ATTENUATION COEFFICIENT SLOPE OF LIVER [J].
AFSCHRIFT, M ;
CUVELIER, C ;
RINGOIR, S ;
BARBIER, F .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1987, 13 (03) :135-139
[2]  
AFSCHRIFT M, 1989, ULTRASONIC TISSUE CH, V7, P9
[3]   ACOUSTIC PROPERTIES OF NORMAL AND CANCEROUS HUMAN-LIVER .2. DEPENDENCE ON TISSUE STRUCTURE [J].
BAMBER, JC ;
HILL, CR ;
KING, JA .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1981, 7 (02) :135-144
[4]  
BENDER DA, 1965, J AM GERIATR SOC, V13, P192
[5]   OPTIMAL PRECISION IN ULTRASOUND ATTENUATION ESTIMATION AND APPLICATION TO THE DETECTION OF DUCHENNE MUSCULAR-DYSTROPHY CARRIERS [J].
BERGER, G ;
LAUGIER, P ;
FINK, M ;
PERRIN, J .
ULTRASONIC IMAGING, 1987, 9 (01) :1-17
[6]  
CARSON PL, 1989, ULTRASONIC IMAG, V11, P138
[7]   INVITRO ESTIMATION OF ACOUSTIC PARAMETERS OF THE LIVER AND CORRELATIONS WITH HISTOLOGY [J].
CLOOSTERMANS, MJTM ;
MOL, H ;
VERHOEF, WA ;
THIJSSEN, JM ;
KUBAT, K .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1986, 12 (01) :39-51
[8]   A BEAM CORRECTED ESTIMATION OF THE FREQUENCY-DEPENDENT ATTENUATION OF BIOLOGICAL TISSUES FROM BACKSCATTERED ULTRASOUND [J].
CLOOSTERMANS, MJTM ;
THIJSSEN, JM .
ULTRASONIC IMAGING, 1983, 5 (02) :136-147
[9]  
COHEN T, 1960, Geriatrics, V15, P824
[10]   ULTRASONIC CHARACTERIZATION OF TISSUE STRUCTURE IN THE INVIVO HUMAN-LIVER AND SPLEEN [J].
FELLINGHAM, LL ;
SOMMER, FG .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1984, 31 (04) :418-428