EVALUATION OF THE PRECISION OF SYSTEMATIC-SAMPLING - NUGGET EFFECT AND COVARIOGRAM MODELING

被引:19
作者
THIOULOUSE, J
ROYET, JP
PLOYE, H
HOULLIER, F
机构
[1] UNIV LYON 1,PHYSIOL NEUROSENSORIELLE LAB,CNRS,URA 180,F-69622 VILLEURBANNE,FRANCE
[2] ECOLE NATL GENIE RURAL EAUX & FORETS,RECH SCI FORESTIERES LAB,F-54042 NANCY,FRANCE
来源
JOURNAL OF MICROSCOPY-OXFORD | 1993年 / 172卷
关键词
STEREOLOGY; VOLUME ESTIMATION; SERIAL SECTIONS; SYSTEMATIC SAMPLING; SAMPLING INTENSITY; SAMPLING PRECISION; REGIONALIZED VARIABLES; NUGGET EFFECT; OLFACTORY BULB; RODENT; TRANSITIVE COVARIOGRAM; MORPHOMETRIC ESTIMATIONS;
D O I
10.1111/j.1365-2818.1993.tb03419.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
Systematic sampling designs are widely used in stereology. When an estimator of the total amount, Q, of the sampled variable is evaluated by such a procedure, the coefficient of error can be predicted by applying Matheron's theory of regionalized variables. To evaluate the accuracy of the estimate of Q, it is necessary to study the behaviour of the regionalized variable and to model its covariogram. Histological. data with a low short-range variability and agronomic data with a pronounced nugget effect provided the biological material for extreme case studies. Results show that the short-range variability, if present, cannot be detected when only small samples are available. An underestimation of the coefficient of error is then to be expected. We propose several models of the covariogram, which can be used to test for the presence of a nugget effect. If a nugget effect is present, these models will provide better estimates of the coefficient of error. If there is no nugget effect a simplified method can be used and will provide reliable estimates of the coefficient of error.
引用
收藏
页码:249 / 256
页数:8
相关论文
共 23 条
[11]   PRECISION OF AREA ESTIMATION - A NUMERICAL STUDY [J].
MATERN, B .
JOURNAL OF MICROSCOPY-OXFORD, 1989, 153 :269-284
[12]  
MATERN B, 1960, MEDDELANDEN STATINS, V49
[13]  
Matheron G., 1970, CAHIERS CTR MORPHOLO, P211
[14]  
Matheron G, 1965, VARIABLES REGIONALIS
[15]   THE ACCURACY OF ONE-DIMENSIONAL SYSTEMATIC-SAMPLING [J].
MATTFELDT, T .
JOURNAL OF MICROSCOPY-OXFORD, 1989, 153 :301-313
[16]   APPLICATION OF THE CAVALIERI PRINCIPLE AND VERTICAL SECTIONS METHOD TO LUNG - ESTIMATION OF VOLUME AND PLEURAL SURFACE-AREA [J].
MICHEL, RP ;
CRUZORIVE, LM .
JOURNAL OF MICROSCOPY, 1988, 150 :117-136
[17]   UNBIASED ESTIMATION OF HUMAN-BODY COMPOSITION BY THE CAVALIERI METHOD USING MAGNETIC-RESONANCE-IMAGING [J].
ROBERTS, N ;
CRUZORIVE, LM ;
REID, NMK ;
BRODIE, DA ;
BOURNE, M ;
EDWARDS, RHT .
JOURNAL OF MICROSCOPY-OXFORD, 1993, 171 :239-253
[18]   MORPHOMETRIC MODIFICATIONS ASSOCIATED WITH EARLY SENSORY EXPERIENCE IN THE RAT OLFACTORY-BULB .2. STEREOLOGICAL STUDY OF THE POPULATION OF OLFACTORY GLOMERULI [J].
ROYET, JP ;
JOURDAN, F ;
PLOYE, H ;
SOUCHIER, C .
JOURNAL OF COMPARATIVE NEUROLOGY, 1989, 289 (04) :594-609
[19]   MORPHOMETRIC MODIFICATIONS ASSOCIATED WITH EARLY SENSORY EXPERIENCE IN THE RAT OLFACTORY-BULB .1. VOLUMETRIC STUDY OF THE BULBAR LAYERS [J].
ROYET, JP ;
JOURDAN, F ;
PLOYE, H .
JOURNAL OF COMPARATIVE NEUROLOGY, 1989, 289 (04) :586-593
[20]  
THIOULOUSE J, 1985, CR ACAD SCI III-VIE, V301, P423