METHODS FOR ESTIMATION OF SUBSAMPLE TIME DELAYS OF DIGITIZED ECHO SIGNALS

被引:339
作者
CESPEDES, I [1 ]
HUANG, Y [1 ]
OPHIR, J [1 ]
SPRATT, S [1 ]
机构
[1] DIASON ULTRASOUND INC,SAN JOSE,CA
关键词
BIAS ERROR; CRAMER-RAO; LOWER BOUND; CURVE FITTING; ELASTOGRAPHY; INTERPOLATION; SIGNAL RECONSTRUCTION; TIME DELAY ESTIMATION; ULTRASOUND;
D O I
10.1006/uimg.1995.1007
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Time delay estimation (TDE) is commonly performed in practice by crosscorrelation of digitized echo signals. Since time delays are generally not integral multiples of the sampling period, the location of the largest sample of the crosscorrelation function (ccf) is an inexact estimator of the location of the peak. Therefore, one must interpolate between the samples of the ccf to improve the estimation precision. Using theory and simulations, we review and compare the performance of several methods for interpolation of the ccf. The maximum likelihood approach to interpolation is the application of a reconstruction filter to the discrete ccf. However, this method can only be approximated in practice and can be computationally intensive. For these reasons, a simple method is widely used that involves fitting a parabola (or other curve) to samples of the ccf in the neighborhood of its peak. We describe and compare two curve-fitting methods: parabolic and cosine interpolation. Curve-fitting interpolation can yield biased time-delay estimates, which may preclude the use of these methods in some applications. The artifactual effect of these bias errors on elasticity imaging by elastography is discussed. We demonstrate that reconstructive interpolation is unbiased. An iterative implementation of the reconstruction procedure is proposed that can reduce the computation time significantly. (C) 1995 Academic Press, Inc.
引用
收藏
页码:142 / 171
页数:30
相关论文
共 29 条
[1]  
Bendat J. S., 2010, RANDOM DATA ANAL MEA
[2]  
BONNEFOUS O, 1990, Patent No. 4928698
[3]   ANALYSIS OF DISCRETE IMPLEMENTATION OF GENERALIZED CROSS CORRELATOR [J].
BOUCHER, RE ;
HASSAB, JC .
IEEE TRANSACTIONS ON ACOUSTICS SPEECH AND SIGNAL PROCESSING, 1981, 29 (03) :609-611
[4]   DIFFRACTION CORRECTION METHODS FOR PULSE-ECHO ACOUSTIC ATTENUATION ESTIMATION [J].
CESPEDES, I ;
OPHIR, J .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (07) :707-717
[5]   REDUCTION OF IMAGE NOISE IN ELASTOGRAPHY [J].
CESPEDES, I ;
OPHIR, J .
ULTRASONIC IMAGING, 1993, 15 (02) :89-102
[6]  
CESPEDES I, 1993, THESIS U HOUSTON TEX
[7]   EXACT MAXIMUM-LIKELIHOOD TIME-DELAY ESTIMATION FOR SHORT OBSERVATION INTERVALS [J].
CHAMPAGNE, B ;
EIZENMAN, M ;
PASUPATHY, S .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 1991, 39 (06) :1245-1257
[8]  
CUSANI R, 1993, COHERENCE TIME DELAY, P78
[9]   EXPERIMENTAL EVALUATION OF THE CORRELATION INTERPOLATION TECHNIQUE TO MEASURE REGIONAL TISSUE VELOCITY [J].
DEJONG, PGM ;
ARTS, T ;
HOEKS, APG ;
RENEMAN, RS .
ULTRASONIC IMAGING, 1991, 13 (02) :145-161
[10]   DETERMINATION OF TISSUE MOTION VELOCITY BY CORRELATION INTERPOLATION OF PULSED ULTRASONIC ECHO SIGNALS [J].
DEJONG, PGM ;
ARTS, T ;
HOEKS, APG ;
RENEMAN, RS .
ULTRASONIC IMAGING, 1990, 12 (02) :84-98