MAGNETIC-RESONANCE ANGIOGRAPHY OF INTRACRANIAL ANEURYSMS - COMPARISON WITH INTRAARTERIAL DIGITAL SUBTRACTION ANGIOGRAPHY

被引:81
作者
SCHUIERER, G
HUK, WJ
LAUB, G
机构
[1] UNIV ERLANGEN NURNBERG,DEPT NEURORADIOL,NEUROCHIRURG KLIN,W-8520 ERLANGEN,GERMANY
[2] SIEMENS AG,UB MED,W-8520 ERLANGEN,GERMANY
关键词
INTRACRANIAL ANEURYSM; MAGNETIC RESONANCE ANGIOGRAPHY; DIGITAL ANGIOGRAPHY;
D O I
10.1007/BF00588279
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Magnetic resonance angiography (MRA) with flow rephased gradient-echo sequences is a new non-invasive method for vascular imaging. We compared MRA and intra-arterial digital subtraction angiography in 18 patients with intracranial aneurysms to test whether MRA presently provides an alternative to cerebral angiography for the diagnosis of these anomalies. MRA showed 19 of the 22 aneurysms detected (86.4 %). However, problems, especially with turbulent or slow flow, resulted in 6 studies (27.3 %) with limited and 2 with questionable demonstration of an aneurysm, and 1 false negative study. At present, MRA is definitely inferior to angiography for the demonstration of intracranial aneurysms, due to its lower resolution and other limitations.
引用
收藏
页码:50 / 54
页数:5
相关论文
共 8 条
[1]  
HUBER P, 1979, ZEREBRALE ANGIOGRAPH
[2]   MR ANGIOGRAPHY WITH GRADIENT MOTION REFOCUSING [J].
LAUB, GA ;
KAISER, WA .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (03) :377-382
[3]   INPLANE VASCULAR IMAGING - PULSE SEQUENCE DESIGN AND STRATEGY [J].
LENZ, GW ;
HAACKE, EM ;
MASARYK, TJ ;
LAUB, G .
RADIOLOGY, 1988, 166 (03) :875-882
[4]   3-DIMENSIONAL (VOLUME) GRADIENT-ECHO IMAGING OF THE CAROTID BIFURCATION - PRELIMINARY CLINICAL-EXPERIENCE [J].
MASARYK, TJ ;
MODIC, MT ;
RUGGIERI, PM ;
ROSS, JS ;
LAUB, G ;
LENZ, GW ;
TKACH, JA ;
HAACKE, EM ;
SELMAN, WR ;
HARIK, SI .
RADIOLOGY, 1989, 171 (03) :801-806
[5]   GIANT INTRACRANIAL ANEURYSMS - MR IMAGING [J].
OLSEN, WL ;
BRANTZAWADZKI, M ;
HODES, J ;
NORMAN, D ;
NEWTON, TH .
RADIOLOGY, 1987, 163 (02) :431-435
[6]   INTRACRANIAL ANEURYSMS - EVALUATION BY MR ANGIOGRAPHY [J].
ROSS, JS ;
MASARYK, TJ ;
MODIC, MT ;
RUGGIERI, PM ;
HAACKE, EM ;
SELMAN, WR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (01) :159-165
[7]   INTRACRANIAL CIRCULATION - PULSE-SEQUENCE CONSIDERATIONS IN 3-DIMENSIONAL (VOLUME) MR ANGIOGRAPHY [J].
RUGGIERI, PM ;
LAUB, GA ;
MASARYK, TJ ;
MODIC, MT .
RADIOLOGY, 1989, 171 (03) :785-791
[8]   3-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY IN THE EVALUATION OF CEREBRAL ANEURYSMS [J].
SEVICK, RJ ;
TSURUDA, JS ;
SCHMALBROCK, P .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (06) :874-881