FRACTIONATION OF CARRIER AMPHOLYTES IN MULTICOMPARTMENT ELECTROLYZERS WITH ISOELECTRIC MEMBRANES

被引:17
作者
BOSSI, A [1 ]
RIGHETTI, PG [1 ]
机构
[1] UNIV CALABRIA,DEPT CELL BIOL,ARCAVACATA,ITALY
关键词
CARRIER AMPHOLYTES; ISOELECTRIC FOCUSING; ISOELECTRIC MEMBRANES; IMMOBILIZED PH GRADIENTS; MULTICOMPARTMENT ELECTROLYZER;
D O I
10.1002/elps.11501601319
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Multicompartment electrolyzers with isoelectric membranes can be successfully utilized for the preparation of carrier ampholytes of narrow pH ranges from commercially available wider pH intervals. An example is given on the preparation of a 0.6 pH unit (pH 6.7-7.3) range from a standard pH 6-8 interval. A 10% Ampholine solution is focused in an electrolyzer equipped with the following isoelectric membranes: pI 6.0, 6.7, 7.3 and 8.0. The narrow pH 6.7-7.3 cut can be efficiently utilized for base-line separation and quantitation of hemoglobin A from its glycated form, Hb A,,. This analysis is important for the screening and follow up of diabetic patients. The advantage of multicompartment electrolyzers are: (i) precision in the preparation of narrow pH cuts, due to the presence of membranes with defined pr values; (ii) ability to perform in both small- and large-scale operations and (iii) absence of contaminants leaching from granulated supports, as typical of some previous techniques.
引用
收藏
页码:1930 / 1934
页数:5
相关论文
共 32 条
[1]   HEMOGLOBIN A1C SEPARATION BY ISOELECTRIC-FOCUSING [J].
BECCARIA, L ;
CHIUMELLO, G ;
GIANAZZA, E ;
LUPPIS, B ;
RIGHETTI, PG .
AMERICAN JOURNAL OF HEMATOLOGY, 1978, 4 (04) :367-374
[2]  
BRETON J, 1995, J CHROMATOGR A, V706, P463
[3]   CARRIER AMPHOLYTE DISTRIBUTION IN ISOELECTRIC-FOCUSING [J].
BROWN, RK ;
CASPERS, ML ;
LULL, JM ;
VINOGRADOV, SN ;
FELGENHAUER, K ;
NEKIC, M .
JOURNAL OF CHROMATOGRAPHY, 1977, 131 (JAN21) :223-232
[4]   LIMITING FACTORS FOR THE RESOLVING POWER OF ISOELECTRIC-FOCUSING IN NATURAL PH GRADIENTS [J].
CHARLIONET, R ;
MORCAMP, C ;
SESBOUE, R ;
MARTIN, JP .
JOURNAL OF CHROMATOGRAPHY, 1981, 205 (02) :355-366
[5]   NEONATAL SCREENING OF BETA-THALASSEMIAS BY THIN-LAYER ISOELECTRIC-FOCUSING [J].
COSSU, G ;
MANCA, M ;
PIRASTRU, MG ;
BULLITTA, R ;
BOSISIO, AB ;
GIANAZZA, E ;
RIGHETTI, PG .
AMERICAN JOURNAL OF HEMATOLOGY, 1982, 13 (02) :149-157
[6]   PURIFICATION OF RECOMBINANT HUMAN GROWTH-HORMONE BY ISOELECTRIC-FOCUSING IN A MULTICOMPARTMENT ELECTROLYZER WITH IMMOBILINE MEMBRANES [J].
ETTORI, C ;
RIGHETTI, PG ;
CHIESA, C ;
FRIGERIO, F ;
GALLI, G ;
GRANDI, G .
JOURNAL OF BIOTECHNOLOGY, 1992, 25 (03) :307-318
[7]   CONTINUOUS-FLOW ISOELECTRIC FOCUSING AND ISOTACHOPHORESIS [J].
FAWCETT, JS .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1973, 209 (JUN15) :112-126
[8]  
GELFI C, 1983, J BIOCHEM BIOPH METH, V8, P156
[9]   PH GRADIENT SIMULATOR FOR ELECTROPHORETIC TECHNIQUES IN A WINDOWS ENVIRONMENT [J].
GIAFFREDA, E ;
TONANI, C ;
RIGHETTI, PG .
JOURNAL OF CHROMATOGRAPHY, 1993, 630 (1-2) :313-327
[10]   FRACTIONATION OF CARRIER AMPHOLYTES FOR ISOELECTRIC FOCUSING [J].
GIANAZZA, E ;
PAGANI, M ;
LUZZANA, M ;
RIGHETTI, PG .
JOURNAL OF CHROMATOGRAPHY, 1975, 109 (02) :357-364