CHARACTERIZATION OF A NEW REVERSED-PHASE CHROMATOGRAPHIC COLUMN ON A 2-MU-M POROUS MICROSPHERICAL SILICA-GEL

被引:22
作者
MORIYAMA, H
ANEGAYAMA, M
KOMIYA, K
KATO, Y
机构
[1] Separation Centre, Tosoh Co., Yamaguchi, 746, Kaisei-cho 4560, Shinnanyo
关键词
D O I
10.1016/0021-9673(94)00744-T
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The physical and chromatographic properties of a reversed-phase column based on a 2-mu m porous silica gel, TSKgel Super-ODS, were investigated. The Super-ODS column reveals higher column efficiencies (over 200 000 theoretical plates/m) at a higher flow-rate than that on a conventional column. High selectivity for a planar compound on Super-ODS implies that it possesses a polymeric ODS layer. Employing pure silica and a full end-capping procedure resulted in sharp peaks for basic and chelating compounds. To avoid the loss of column efficiency, the void volumes in an operating system such as connecting tubes, eel volume and sample volume, should be minimized as much as possible. The time constant of the detector also affected the column efficiency. The separation of peptides was achieved within 4 min.
引用
收藏
页码:81 / 89
页数:9
相关论文
共 17 条
[1]  
CREMER SM, 1984, J CHROMATOGR, V295, P405
[2]   SYNTHESIS AND CHARACTERIZATION OF 2-MU-M WIDE-PORE SILICA MICROSPHERES AS COLUMN PACKINGS FOR THE REVERSED-PHASE LIQUID-CHROMATOGRAPHY OF PEPTIDES AND PROTEINS [J].
DANIELSON, ND ;
KIRKLAND, JJ .
ANALYTICAL CHEMISTRY, 1987, 59 (20) :2501-2506
[3]   PACKING TECHNOLOGY, COLUMN BED STRUCTURE AND CHROMATOGRAPHIC PERFORMANCE OF 1-2-MU-M NON-POROUS SILICAS IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
GIESCHE, H ;
UNGER, KK ;
ESSER, U ;
ERAY, B ;
TRUDINGER, U ;
KINKEL, JN .
JOURNAL OF CHROMATOGRAPHY, 1989, 465 (01) :39-57
[4]   CORRELATION BETWEEN THE RETENTION DATA OF POLYCYCLIC AROMATIC-HYDROCARBONS AND SEVERAL DESCRIPTORS IN REVERSED-PHASE HPLC [J].
JINNO, K ;
KAWASAKI, K .
CHROMATOGRAPHIA, 1983, 17 (08) :445-449
[5]   RAPID PEPTIDE-MAPPING BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
KALGHATGI, K ;
HORVATH, C .
JOURNAL OF CHROMATOGRAPHY, 1988, 443 :343-354
[6]   HIGH-PERFORMANCE ION-EXCHANGE CHROMATOGRAPHY OF PROTEINS ON NONPOROUS ION-EXCHANGERS [J].
KATO, Y ;
KITAMURA, T ;
MITSUI, A ;
HASHIMOTO, T .
JOURNAL OF CHROMATOGRAPHY, 1987, 398 :327-334
[7]   HIGH-PERFORMANCE HYDROPHOBIC INTERACTION CHROMATOGRAPHY OF PROTEINS ON A PELLICULAR SUPPORT BASED ON HYDROPHILIC RESIN [J].
KATO, Y ;
KITAMURA, T ;
NAKATANI, S ;
HASHIMOTO, T .
JOURNAL OF CHROMATOGRAPHY, 1989, 483 :401-405
[8]  
KATO Y, 1988, J CHROMATOGR, V481, P212
[9]  
KEITH J, 1987, J CHROMATOGR, V397, P3
[10]   COMPREHENSIVE CHARACTERIZATION OF SOME SILICA-BASED STATIONARY PHASES FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
KOHLER, J ;
CHASE, DB ;
FARLEE, RD ;
VEGA, AJ ;
KIRKLAND, JJ .
JOURNAL OF CHROMATOGRAPHY, 1986, 352 :275-305