摘要
A modified crossover surface coil with minimal B1 field penetration was used for collection of skin phosphorus NMR spectra. Projection imaging experiments show that the coilsensitive volume is uniform at the phosphorus frequency, but strikingly nonuniform at s the proton frequency. Experiments with an in vitro phosphorus phantom, designed to simulate skin and underlying tissue, demonstrated that 45.1% (±1.2%) of total signal was derived from Sprague‐Dawley rat skin and 19.3% (±1.4%) of total signal was derived from Fischer‐344 rat skin. 31P MR spectra of rat skin in vivo permitted resolution of four phosphorus compounds: nucleoside triphosphates, phosphocreatine (PCr), inorganic phosphate (Pi), and phosphomonoester. Spectra collected after skin flap surgery in Fischer‐344 rats showed a 50.1% (±7.6%) reduction in the ratio of PCr/Pi within 30 min of surgery, compared to presurgical PCr/Pi levels (P < 0.01). Skin phosphorus spectra are potentially useful for assessment of skin flap and skin graft viability. © 1992 Academic Press, Inc. Copyright © 1992 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:46 / 54
页数:9
相关论文
共 17 条
[1]  
CUONO CB, 1988, PLAST RECONSTR SURG, V81, P1
[2]  
CUONO CB, 1987, SURGERY, V102, P263
[3]   ON THE MECHANISM BY WHICH ANTIADRENERGIC DRUGS INCREASE SURVIVAL OF CRITICAL SKIN FLAPS [J].
JURELL, G ;
HJEMDAHL, P ;
FREDHOLM, BB .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1983, 72 (04) :518-523
[4]   USE OF MAGNETIC-RESONANCE SPECTROSCOPY IN THE EVALUATION OF SKIN FLAP CIRCULATION [J].
KLEIN, HW ;
GOURLEY, IM .
ANNALS OF PLASTIC SURGERY, 1988, 20 (06) :547-551
[5]   ASSESSING BURN WOUND DEPTH USING INVITRO NUCLEAR-MAGNETIC-RESONANCE (NMR) [J].
KORUDA, MJ ;
ZIMBLER, A ;
SETTLE, RG ;
JACOBS, DO ;
ROLANDELLI, RH ;
WOLF, GL ;
ROMBEAU, JL .
JOURNAL OF SURGICAL RESEARCH, 1986, 40 (05) :475-481
[6]  
LENKINSKI RE, 1988, SOC MAGNETIC RESONAN, V1, P325
[7]   DYNAMIC VARIATIONS IN BLOOD-FLOW AS MEASURED BY LASER DOPPLER VELOCIMETRY - A STUDY IN RAT SKIN FLAPS [J].
MARKS, NJ ;
TRACHY, RE ;
CUMMINGS, CW .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1984, 73 (05) :804-810
[8]  
MCFARLANE R M, 1965, Plast Reconstr Surg, V35, P177, DOI 10.1097/00006534-196502000-00007
[9]   AN INVIVO NMR PROBE CIRCUIT FOR IMPROVED SENSITIVITY [J].
MURPHYBOESCH, J ;
KORETSKY, AP .
JOURNAL OF MAGNETIC RESONANCE, 1983, 54 (03) :526-532
[10]   THE CROSSOVER SURFACE COIL - AN EFFICIENT INVIVO NMR DETECTOR [J].
NAGEL, TL ;
STOLK, JA ;
ALDERMAN, DW ;
SCHOENBORN, R ;
SCHWEIZER, MP .
MAGNETIC RESONANCE IN MEDICINE, 1990, 13 (02) :271-278