AIR-COOLING CHARACTERISTICS OF SIMULATED GRAPE PACKAGES

被引:5
作者
FREDERICK, RL
COMUNIAN, F
机构
[1] Universidad de Chile. Departamento de Ingeniería Mecánica. Casilla 2777, Santiago
关键词
D O I
10.1016/0735-1933(94)90012-4
中图分类号
O414.1 [热力学];
学科分类号
摘要
Experimental simulation of the external forced convection on the outside of grape packages was performed. Average heat transfer coefficients for air flow around such containers were found to range from 8 to 13.4 W/(m2K). A physical description of the convective process was formulated on the basis of data obtained in three types of experiment. Expressions for the average heat transfer coefficient from single packages in air flow were proposed.
引用
收藏
页码:447 / 458
页数:12
相关论文
共 6 条
[1]  
Baird C. D., 1976, ASHRAE T, V82, P525
[2]   LOCAL HEAT MASS-TRANSFER DISTRIBUTIONS ON THE SURFACE OF A WALL-MOUNTED CUBE [J].
CHYU, MK ;
NATARAJAN, V .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1991, 113 (04) :851-857
[3]   LOCAL HEAT-TRANSFER FROM A SQUARE PRISM TO AN AIRSTREAM [J].
IGARASHI, T .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1986, 29 (05) :777-784
[4]   HEAT-TRANSFER FROM A SQUARE PRISM TO AN AIR STREAM [J].
IGARASHI, T .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1985, 28 (01) :175-181
[5]  
Kreith F., 2011, PRINCIPLES HEAT TRAN
[6]  
Nelson KE., 1985, HARVESTING HANDLING