AERATED ANOXIC BIOLOGICAL NDEN PROCESS

被引:6
作者
ALBERTSON, OE [1 ]
STENSEL, HD [1 ]
机构
[1] UNIV WASHINGTON,DEPT CIVIL ENGN,SEATTLE,WA 98195
关键词
ACTIVATED SLUDGE; NITRIFICATION; DENITRIFICATION; AERATED ANOXIC; BIO-SELECTION; UPGRADING FOR NUTRIENT REMOVAL; NITROSOMONAS AND NITROBACTER GROWTH RATES;
D O I
10.2166/wst.1994.0334
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The conventional practice for an anoxic denitrification basin has been to minimize oxygen input on the basis that if is detrimental to the process. For existing secondary treatment systems, allotting 25-35% of the aeration volume for an unaerated anoxic zone will significantly reduce plant capacity. Further one group has held that bulking control is best achieved by eliminating all forms of oxygen from the initial contact or biological selector zones. The Phoenix 91st Avenue WWTP was designed with nitrate recycle to aerated selector zones and the anoxic zones were provided with a dense array of fine bubble diffusers. The prototype NdeN process was able to maintain the 1.31 m(3)/s secondary capacity with aerated anoxic zone receiving 20-25% of the total airflow. Net sludge yields were 30-50% higher than anticipated due to Primary clarifier solids losses at higher flows which reduced SRT(T) to less than or equal to 5 days. At 5.0-5.5 day SRT(T), effluent averaged 8.3 mg/L TN, 1.75 mg/L NH4N and 5.7 mg/L NO3N. Nitrobacter N oxidation rates were unexplainably lower than the Nitrosomonas N oxidation rates causing effluent NO2N.
引用
收藏
页码:167 / 176
页数:10
相关论文
共 4 条
[1]   BULKING AND FOAMING ORGANISM CONTROL AT PHOENIX, AZ WWTP [J].
ALBERTSON, OE ;
HENDRICKS, P .
WATER SCIENCE AND TECHNOLOGY, 1992, 26 (3-4) :461-472
[2]  
ALBERTSON OE, 1992, WATER SCI TECHNOL, V25, P4
[3]  
JANSEN JLC, 1979, PROGR WATER TECHNOL, V12, P521
[4]  
STENSEL HD, 1981, WATER AM I CHEM ENG, P237