THE GAMMA-NAIL FOR PERITROCHANTERIC FRACTURES

被引:139
作者
HALDER, SC
机构
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 1992年 / 74卷 / 03期
关键词
D O I
10.1302/0301-620X.74B3.1587873
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The Gamma nail was designed to treat unstable intertrochanteric and subtrochanteric fractures. The device was developed after cadaver studies and has been used clinically since February 1985 in a total of 421 patients. The results in 123 patients treated by the third version of this design are reported. The Gamma nail transmits weight closer to the calcar than does the dynamic hip screw and it has greater mechanical strength. A semi-closed operative technique is used, with an average duration of operation of 35 minutes and little blood loss. Distal locking screws can be used to maintain rotational stability, and can be inserted without the use of an image intensifier. Results showed satisfactory fracture union with little loss of position, even in comminuted fractures. Operative complications were few, but included fractures of the base of the greater trochanter. The most important postoperative complication, seen in one case, was fracture of the shaft of the femur at the distal end of the nail, but this healed well after re-nailing.
引用
收藏
页码:340 / 344
页数:5
相关论文
共 18 条
[1]   FATIGUE FRACTURE OF A FEMORAL SLIDING COMPRESSION SCREW-PLATE DEVICE AFTER BONE UNION [J].
AMIS, AA ;
BROMAGE, JD ;
LARVIN, M .
BIOMATERIALS, 1987, 8 (02) :153-157
[2]  
Ashby M E, 1977, J Natl Med Assoc, V69, P623
[3]  
BANNISTER GC, 1983, J BONE JOINT SURG BR, V65, P218
[4]   SUBTROCHANTERIC FRACTURE OF THE FEMUR - FIXATION USING THE ZICKEL NAIL [J].
BERGMAN, GD ;
WINQUIST, RA ;
MAYO, KA ;
HANSEN, ST .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1987, 69A (07) :1032-1040
[5]   FIXATION OF INTERTROCHANTERIC FRACTURES OF THE FEMUR - A RANDOMIZED PROSPECTIVE COMPARISON OF THE GAMMA-NAIL AND THE DYNAMIC HIP SCREW [J].
BRIDLE, SH ;
PATEL, AD ;
BIRCHER, M ;
CALVERT, PT .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (02) :330-334
[6]  
CHANG WS, 1987, CLIN ORTHOP RELAT R, V225, P141
[7]   INTERTROCHANTERIC FEMORAL FRACTURES - MECHANICAL FAILURE AFTER INTERNAL-FIXATION [J].
DAVIS, TRC ;
SHER, JL ;
HORSMAN, A ;
SIMPSON, M ;
PORTER, BB ;
CHECKETTS, RG .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (01) :26-31
[8]   TROCHANTERIC FRACTURES OF THE FEMUR - A RANDOMIZED PROSPECTIVE TRIAL COMPARING THE JEWETT NAIL-PLATE WITH THE DYNAMIC HIP SCREW [J].
ESSER, MP ;
KASSAB, JY ;
JONES, DHA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1986, 68 (04) :557-560
[9]  
Friedl W, 1987, Unfallchirurgie, V13, P1, DOI 10.1007/BF02585823
[10]  
HALDER SC, 1991, OPERATIVE TECHNIQUE