EXAMINATION OF INTERNATIONAL NORMALIZED RATIO (INR) IMPRECISION BY COMPARISON OF EXACT AND APPROXIMATE FORMULAS

被引:7
作者
BENNETT, ST
CRITCHFIELD, GC
机构
[1] IHC,LAB SERV,SALT LAKE CITY,UT
[2] UNIV UTAH,SCH MED,DEPT PATHOL,SALT LAKE CITY,UT
[3] UTAH VALLEY REG MED CTR,DEPT PATHOL,PROVO,UT
[4] BRIGHAM YOUNG UNIV,DEPT MICROBIOL,PROVO,UT 84602
关键词
D O I
10.1136/jcp.47.7.635
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Aim-To evaluate the accuracy of the approximate linear formula of International Normalised Ratio (INR) imprecision by formal mathematical analysis. Methods-Using probability theory, an exact formula for the coefficient of variation (CV) of the INR was derived. The CV from the approximate formula was compared with the CV from the exact formula for INR determinations between 1.0 and 10.0 with International Sensitivity Indices (ISIs) between 1.0 and 3.0 and prothrombin time ratio CVs between 1.0 and 10.0%. Results-When the ISI equals 1.0, the approximate formula and the exact formula are equal. When the ISI is more than 1.0, the approximate formula overestimates the exact CV, but by less than one hundredth of the exact CV in the parameter ranges studied. The approximate formula is most accurate when laboratories achieve excellent prothrombin time measurement precision and use sensitive thromboplastins. Conclusions-The approximate formula provides a simple means for estimating the imprecision of the INR and is sufficiently accurate to warrant its use in clinical laboratories.
引用
收藏
页码:635 / 638
页数:4
相关论文
共 8 条
[1]  
BERS L, 1969, CALCULUS
[2]   THE INTERNATIONAL NORMALIZED RATIO AND UNCERTAINTY - VALIDATION OF A PROBABILISTIC MODEL [J].
CRITCHFIELD, GC ;
BENNETT, ST .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1994, 102 (01) :115-122
[3]   EFFECT OF LABORATORY VARIATION IN THE PROTHROMBIN-TIME RATIO ON THE RESULTS OF ORAL ANTICOAGULANT-THERAPY [J].
ECKMAN, MH ;
LEVINE, HJ ;
PAUKER, SG .
NEW ENGLAND JOURNAL OF MEDICINE, 1993, 329 (10) :696-702
[4]   ORAL ANTICOAGULANTS - MECHANISM OF ACTION, CLINICAL EFFECTIVENESS, AND OPTIMAL THERAPEUTIC RANGE [J].
HIRSH, J ;
DALEN, JE ;
DEYKIN, D ;
POLLER, L .
CHEST, 1992, 102 (04) :S312-S326
[5]  
LINDGREN BW, 1981, STATISTICAL THEORY, P137
[6]  
LOELIGER EA, 1982, LANCET, V2, P318
[7]   EFFECT OF INTERNATIONAL SENSITIVITY INDEX (ISI) OF THROMBOPLASTINS ON PRECISION OF INTERNATIONAL NORMALIZED RATIOS (INR) [J].
TABERNER, DA ;
POLLER, L ;
THOMSON, JM ;
DARBY, KV .
JOURNAL OF CLINICAL PATHOLOGY, 1989, 42 (01) :92-96
[8]  
1981, WHO TECHNICAL REPORT, V658, P185