Adsorption of Anti-human IgG to Plasma-polymerized Allylamine Film Formed on a Silver Plate

被引:11
作者
Kurosawa, Shigeru [1 ]
Kamo, Naoki [1 ]
Muratsugu, Makoto [2 ]
机构
[1] Hokkaido Univ, Fac Pharmaceut Sci, Sapporo, Hokkaido 060, Japan
[2] Asahikawa Med Coll, Dept Lab Med, Asahikawa, Hokkaido 078, Japan
关键词
Plasma-polymerized allylamine; silver plate; Isotherm of F(ab ')(2) anti-human IgG binding;
D O I
10.1002/pat.1991.220020507
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Increase in the sensitivity of an immunosensor or bio-sensor requires the immobilization of a large amount of proteins. Good materials must be developed for this protein adsorption. Allylamine thin film was formed on a pat silver plate by plasma polymerization; this plate is referred to as Ag(ALAM).Ag(ALAM) films were characterized by SEM, FT-IR and ESCA. Investigations on adsorption and desorption of F(ab')(2) anti-human IgG (hlgG) on to Ag and Ag(ALAM) revealed the following: (1) The adsorption isotherm of F(ab')(2), anti-hIgG on to AG(ALAM) or Ag was of a Langmuir type. The binding constant (K-b) and saturation binding (A(b)) for this protein on to Ag(ALAM) were 8.93 l/mol and 181.8 nmol/m(2), respectively, and for Ag, were 7.71 l/mole and 87.9 nmol/m(2). (2) The extent of desorption of labeled F(ab')(2), anti-hIgG absorbed on the two plates was the same. (3) Ag(ALAM) and Ag were used as solid phases in a two-site immunoradiometric assay of human serum IgG. The dose-response on AG(ALAM) occurred at lower concentration, and was of greater magnitude than that on AS.
引用
收藏
页码:253 / 259
页数:7
相关论文
共 25 条
[1]  
Bolton A. E., 1986, HDB EXPT IMMUNOLOGY, V1
[2]   CONTINUOUS LIQUID-PHASE PIEZOELECTRIC BIOSENSOR FOR KINETIC IMMUNOASSAYS [J].
DAVIS, KA ;
LEARY, TR .
ANALYTICAL CHEMISTRY, 1989, 61 (11) :1227-1230
[3]  
Guilbault G. G., 1984, APPL PIEZOELECTRIC Q
[4]   IMMOBILIZATION METHODS FOR PIEZOELECTRIC BIOSENSORS [J].
GUILBAULT, GG ;
LUONG, JHT ;
PRUSAKSOCHACZEWSKI, E .
BIO-TECHNOLOGY, 1989, 7 (04) :349-351
[5]  
Ikada Y., 1985, NIPPON KAGAKU KAISHI, V1079
[6]  
Ivarsson B., 1986, CRIT BIOCORNPAT, V2
[7]   PLASMA-POLYMERIZED MEMBRANE-ELECTRODE SELECTIVE FOR LIPOPHILIC CATIONS [J].
KUROSAWA, S ;
KAMO, N ;
KOBATAKE, Y ;
TOYASHIMA, I .
JOURNAL OF MEMBRANE SCIENCE, 1989, 46 (2-3) :157-166
[8]  
KUROSAWA S, 1990, CHEM PHARM BULL, V38, P1117
[9]   OSCILLATING FREQUENCY OF PIEZOELECTRIC QUARTZ CRYSTAL IN SOLUTIONS [J].
KUROSAWA, S ;
TAWARA, E ;
KAMO, N ;
KOBATAKE, Y .
ANALYTICA CHIMICA ACTA, 1990, 230 (01) :41-49
[10]   GAS SORPTION TO PLASMA-POLYMERIZED COPPER PHTHALOCYANINE FILM FORMED ON A PIEZOELECTRIC CRYSTAL [J].
KUROSAWA, S ;
KAMO, N ;
MATSUI, D ;
KOBATAKE, Y .
ANALYTICAL CHEMISTRY, 1990, 62 (04) :353-359