A MICROCHANNEL PLATE INTENSIFIED, SUBNANOSECOND, X-RAY-IMAGING CAMERA

被引:4
作者
CARTER, MR
MCKINLEY, BJ
TIRSELL, KG
机构
[1] University of California, Lawrence Livermore National Laboratory, Livermore, CA, 94550, P.O. Box 808
关键词
D O I
10.1088/0031-8949/41/4/002
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
We have developed a microchannel plate intensified, subnanosecond X-ray detector for X-ray imaging experiments. It consists of an X-ray photocathode, a microchannel plate, electrostatic focusing optics and a subnanosecond phosphor. The detector is used for one dimensional imaging and spectroscopic measurements. Signals are recorded using either a one dimensional Reticon camera or a streak camera. The microchannel plates employ an X-ray photocathode (CuI or CsI) deposited on the front surface of the microchannel plate to enhance their soft X-ray efficiency. Electrostatic focusing of the electrons exciting the microchannel plate also enhances the gain of the detector by an order of magnitude. The electrons are accelerated to 20 kV before striking a fast phosphor (indium doped cadmium sulfide). The detector output is coupled to a Reticon camera or a streak camera with a fiber optic array. We have built and calibrated more than twenty microchannel plate intensified detectors. Efficiencies in excess of 1000 (w/cm2 output per w/cm2 input) have been demonstrated. The time response of the detector is less than 500 ps. The efficiency if the CuI and CsI X-ray photocathodes have been measured from 450 eV to 1300 eV at the Stanford Synchrotron Radiation Laboratory. Data are presented on the efficiency, time response, spectral response and the spatial resolution of the detectors. © 1990 IOP Publishing Ltd.
引用
收藏
页码:390 / 395
页数:6
相关论文
共 8 条
[1]   GAIN MODEL FOR MICROCHANNEL PLATES [J].
EBERHARDT, EH .
APPLIED OPTICS, 1979, 18 (09) :1418-1423
[2]   THE CHARACTERIZATION OF X-RAY PHOTO-CATHODES IN THE 0.1-10-KEV PHOTON ENERGY REGION [J].
HENKE, BL ;
KNAUER, JP ;
PREMARATNE, K .
JOURNAL OF APPLIED PHYSICS, 1981, 52 (03) :1509-1520
[3]   ZINC OXIDE AND ZINC-CADMIUM OXIDE PHOSPHORS [J].
LEHMANN, W .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1968, 115 (05) :538-&
[4]   EDGE EMISSION OF N-TYPE CONDUCTING ZNO AND CDS [J].
LEHMANN, W .
SOLID-STATE ELECTRONICS, 1966, 9 (11-1) :1107-&
[5]  
ROTTER MD, 1981, P SOC PHOTO-OPT INST, V296, P183
[6]  
TIRSELL KG, 1988, SPIE, V911, P146
[7]   THE STABILITY OF CSI-COATED MICROCHANNEL PLATE X-RAY-DETECTORS [J].
WHITELEY, MJ ;
PEARSON, JF ;
FRASER, GW ;
BARSTOW, MA .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 224 (1-2) :287-297
[8]   EXPERIMENT DEMONSTRATION OF A 100-PS MICROCHANNEL PLATE FRAMING CAMERA [J].
YOUNG, BKF ;
STEWART, RE ;
WOODWORTH, JG ;
BAILEY, J .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1986, 57 (11) :2729-2732