SOLID-STATE ION-SELECTIVE ELECTRODES FOR THE POTENTIOMETRIC DETERMINATION OF PHOSPHATE

被引:20
作者
MIDGLEY, D
机构
[1] Central Electricity Research Laboratories, Leatherhead, Surrey, Kelvin Avenue
关键词
D O I
10.1016/0039-9140(79)80063-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A number of solid-state ion-selective electrodes for the potentiometric determination of phosphate have been made and their properties investigated. The most successful of these electrodes, which had a membrane comprising silver sulphide, lead sulphide and lead hydrogen phosphate, had a theoretical Nernstian response to orthophosphate ion at concentrations down to 5 μg/ml total phosphate at pH 8.3. The electrode had a slow response and its standard potential changed with time. Anions such as sulphate, bicarbonate and nitrate did not interfere; chloride had a transient effect, but even at its worst the interference was less serious than with other phosphate electrodes. The electrode was used as an indicator in the potentiometric precipitation titration of phosphate and lanthanum. © 1979.
引用
收藏
页码:261 / 266
页数:6
相关论文
共 13 条
[1]  
BUTLER JN, 1964, IONIC EQUILIBRIA MAT
[2]  
Davies C.W., 1962, ION ASS
[3]   STUDY OF VARIOUS INORGANIC PHOSPHATE SALTS IMPREGNATED IN SILICONE RUBBER AS POTENTIAL INDICATING ELECTRODES FOR PHOSPHATE ION [J].
GUILBAULT, GG ;
BRIGNAC, PJ .
ANALYTICAL CHEMISTRY, 1969, 41 (08) :1136-+
[4]   LIQUID-LIQUID ION-EXCHANGE MEMBRANE ELECTRODES WITH HETEROPOLY COMPOUNDS AS ION EXCHANGER FOR PHOSPHATE ION [J].
GUILBAULT, GG ;
BRIGNAC, PJ .
ANALYTICA CHIMICA ACTA, 1971, 56 (01) :139-+
[5]   SELECTRODE - UNIVERSAL ION-SELECTIVE SOLID-STATE ELECTRODE .2. COMPARISON OF COPPER(II) ELECTRODES IN METAL BUFFERS AND COMPLEXIMETRIC TITRATIONS [J].
HANSEN, EH ;
RUZICKA, J ;
LAMM, CG .
ANALYTICA CHIMICA ACTA, 1972, 59 (03) :403-&
[6]   EVALUATION OF SOME COMMERCIAL LEAD(II)-SELECTIVE ELECTRODES [J].
KIVALO, P ;
VIRTANEN, R ;
WICKSTROM, K ;
WILSON, M ;
PUNGOR, E ;
HORVAI, G ;
TOTH, K .
ANALYTICA CHIMICA ACTA, 1976, 87 (02) :401-409
[7]   ACTIVITY OF ORTHOPHOSPHORIC ACID IN AQUEOUS SOLUTIONS AT 25-DEGREES FROM EMF MEASUREMENTS WITH THE LEAD AMALGAM LEAD PHOSPHATE ELECTRODE [J].
MASON, CM ;
BLUM, WM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1947, 69 (06) :1246-1250
[8]   COMPARISON OF COPPER(II) ION-SELECTIVE ELECTRODES FOR MEASUREMENTS AT MICROMOLAR CONCENTRATIONS [J].
MIDGLEY, D .
ANALYTICA CHIMICA ACTA, 1976, 87 (01) :7-17
[9]   DIVALENT PHOSPHATE ELECTRODE [J].
NAGELBERG, I ;
BRADDOCK, LI ;
BARBERO, GJ .
SCIENCE, 1969, 166 (3911) :1403-+
[10]   INVESTIGATION OF POLYPHENYL-ONIUM BASES AND OTHER MATERIALS FOR PHOSPHATE ION-SELECTIVE ELECTRODES [J].
NANJO, M ;
ROHM, TJ ;
GUILBAULT, GG .
ANALYTICA CHIMICA ACTA, 1975, 77 (JUL) :19-27