EXTRA-COLUMN EFFECTS IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .1. THEORETICAL-STUDY OF THE INJECTION PROBLEM

被引:37
作者
COLIN, H
MARTIN, M
GUIOCHON, G
机构
[1] Laboratoire de Chimie Analytique Physique, Ècole Polytechnique, 91128 Palaiseau Cedex, Route de Saclay
来源
JOURNAL OF CHROMATOGRAPHY | 1979年 / 185卷 / DEC期
关键词
D O I
10.1016/S0021-9673(00)85599-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The effect of the injection process on the column efficiency depends on the injection time, the injection volume and the technique of sampling (syringe on-line or stop-flow injection through a septum-type injector port or valve injection in either the normal or the split mode). The injection process can be described by a contribution to the plate height that is proportional to the square of the length of the solute zone at the column inlet (Δx) and iversely proportional to the square of the column length and to a constant describing the concentration profile in the solute zone. A simple model based on the combined effect of solute displacement due to the injection flow and to the mobile phase flow makes possible the calculation of Δ. The effects of injection time and volume and volume are complex and depend on the sampling system and on geometrical parameters such as the column internal cross-sectional area, the sampling canal intenal and external cross-sectional areas and two co- efficients related to the flow pattern at the column inlet. In some conditions, the model proposed predicts, in agreement with experimental results, a non-linear dependence of the plate height on the square of the injection volume. Finally, the influence of particle size on the extra-column effect due to injection depends cosely on the experimental conditions: the results are different when the column is operated at maximal efficiency and when we want to achieve a given number of theoretical plates in a given time. In some instances the injection effect is independent on the particle size and in others it is inversely proportional to dp4. © 1979.
引用
收藏
页码:79 / 95
页数:17
相关论文
共 19 条
[1]  
BROWNLEE RG, 1978, CHROMATOGRAPHIA, V11, P567, DOI 10.1007/BF02268925
[2]   COMPARISON OF SOME PACKINGS FOR REVERSED-PHASE HIGH-PERFORMANCE LIQUID-SOLID CHROMATOGRAPHY .2. SOME THEORETICAL CONSIDERATIONS [J].
COLIN, H ;
GUIOCHON, G .
JOURNAL OF CHROMATOGRAPHY, 1978, 158 (OCT) :183-205
[3]  
COLIN H, UNPUBLISHED
[4]   TECHNIQUES FOR PACKING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC COLUMNS WITH POROUS MICROPARTICLES [J].
COQ, B ;
GONNET, C ;
ROCCA, JL .
JOURNAL OF CHROMATOGRAPHY, 1975, 106 (02) :249-262
[5]  
COQ B, 1979, ANALUSIS, V7, P339
[6]   QUANTITATIVE ANALYSIS OF TRACE AMOUNTS OF ESTROGENIC STEROIDS IN PREGNANCY URINE BY COLUMN LIQUID-LIQUID CHROMATOGRAPHY WITH ULTRAVIOLET DETECTION [J].
HUBER, JFK ;
HULSMAN, JAR ;
MEIJERS, CAM .
JOURNAL OF CHROMATOGRAPHY, 1971, 62 (01) :79-&
[7]   ROLE OF COLUMN PARAMETERS AND INJECTION VOLUME ON DETECTION LIMITS IN LIQUID-CHROMATOGRAPHY [J].
KARGER, BL ;
MARTIN, M ;
GUIOCHON, G .
ANALYTICAL CHEMISTRY, 1974, 46 (12) :1640-1647
[8]   SAMPLING AND EXTRA-COLUMN EFFECTS IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - INFLUENCE OF PEAK SKEW ON PLATE COUNT CALCULATIONS [J].
KIRKLAND, JJ ;
YAU, WW ;
STOKLOSA, HJ ;
DILKS, CH .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1977, 15 (08) :303-316
[9]   EFFECT OF COLUMN TO PARTICLE DIAMETER RATIO ON DISPERSION OF UNSORBED SOLUTES IN CHROMATOGRAPHY [J].
KNOX, JH ;
PARCHER, JF .
ANALYTICAL CHEMISTRY, 1969, 41 (12) :1599-&
[10]   INTERACTION OF RADIAL AND AXIAL-DISPERSION IN LIQUID-CHROMATOGRAPHY IN RELATION TO INFINITE DIAMETER EFFECT [J].
KNOX, JH ;
LAIRD, GR ;
RAVEN, PA .
JOURNAL OF CHROMATOGRAPHY, 1976, 122 (JUL7) :129-145