CORRECTION OF INTENSITY NONUNIFORMITY IN MR IMAGES OF ANY ORIENTATION

被引:121
作者
WICKS, DAG
BARKER, GJ
TOFTS, PS
机构
[1] NMR Research Group, Institute of Neurology, London
关键词
RF UNIFORMITY; IMAGE INTENSITY CORRECTION; INTENSITY THRESHOLD; PROTON DENSITY;
D O I
10.1016/0730-725X(93)90023-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The specialised radiofrequency (RF) coils used in MRI such as head or surface coils can give rise to marked image intensity nonuniformities. There are two situations in which it is essential to correct this: (1) When a global intensity threshold is used to segment particular tissues; and (2) in proton density images, from which the proton concentration can be measured provided that the system gain is uniform or known over the whole image. We describe experiments to determine the magnitude and sources of nonuniformity in a 0.5-T system, and assess methods devised to correct for them in scans of any orientation, including oblique scans at arbitrary angles to the magnet axis and arbitrary offsets from the magnet iso-centre. A correction based on the response of a system to a uniform phantom was implemented. Tests of the correction with orthogonal views demonstrate that the uniformity of images of any orientation can be improved significantly with a correction matrix from just one orientation and still further with two matrices, one axial and the other either coronal or sagittal. We expect further improvements to be possible if gradient coil eddy current effects can be reduced.
引用
收藏
页码:183 / 196
页数:14
相关论文
共 10 条
  • [1] McVeigh, Henkelman, Bronskill, Non-uniform sensitivity of receiver coils in MR imaging, Abstracts of the SMRM, 4, (1985)
  • [2] Axel, Costantini, Listerud, Intensity correction in surface-coil imaging, Am. J. Roentgenol., 148, pp. 418-420, (1987)
  • [3] Fuderer, van Est, Surface coil correction using homomorphic filtering, Abstracts of the SMRM, 6, (1987)
  • [4] Lim, Pfefferbaum, Segmentation of MR brain images into cerebrospinal fluid spaces, white, and grey matter, J. Comput. Assist. Tomogr., 13, pp. 588-593, (1989)
  • [5] Condon, Patterson, Wyper, Jenkins, Hadley, Image non-uniformity in magnetic resonance imaging: Its magnitude and methods for correction, Br. J. Radiol., 60, pp. 83-87, (1987)
  • [6] Tofts, Johnson, Correction for Rayleigh noise in an NMR magnitude image when measuring T<sub>2</sub> at low values of signal to noise ratio, Abstracts of the SMRM, 5, (1986)
  • [7] Johnson, Ormerod, Barnes, Tofts, MacManus, Accuracy and precision in the measurement of relaxation times from nuclear magnetic resonance images, Br. J. Radiol., 60, pp. 143-153, (1987)
  • [8] Chin, Yeh, Quantitative evaluation of some edge preserving noise smoothing techniques, Computer Vision, Graphics and Image Processing, 23, pp. 67-91, (1983)
  • [9] Mastin, Adaptive filters for digital image noise smoothing: An evaluation, Computer Vision, Graphics and Image Processing, 31, pp. 103-121, (1985)
  • [10] Barker, Tofts, Semi-automated quality assurance for quantitative magnetic resonance imaging, Magn. Reson. Imaging, 10, 4, pp. 585-595, (1992)