SAFE USE OF HEPARIN-COATED BYPASS CIRCUITS INCORPORATING A PUMP-OXYGENATOR

被引:13
作者
JONES, DR [1 ]
HILL, RC [1 ]
VASILAKIS, A [1 ]
HOLLINGSED, MJ [1 ]
GRAEBER, GM [1 ]
GUSTAFSON, RA [1 ]
CRUZZAVALA, JL [1 ]
MURRAY, GF [1 ]
机构
[1] W VIRGINIA UNIV, SCH MED, DEPT SURG, MORGANTOWN, WV 26506 USA
关键词
D O I
10.1016/0003-4975(94)90181-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Durable, covalently bonded, heparin-coated cardiopulmonary bypass (CPB) circuits with oxygenators have been developed. Proposed advantages of heparin-coated CPB circuits include improved biocompatibility and thromboresistance. The purpose of this study was to evaluate our experience with heparin-coated CPB circuits in 20 patients. Heparin was given to maintain an activated clotting time equal to or greater than 200 seconds, while now rates were kept equal to or greater than 2 L/min. Indications for use of this circuit included recent stroke, posttraumatic injuries, recent gastrointestinal bleeding, protamine allergies, combined cardiac and noncardiac procedures, and ventricular assist. Mean heparin dosage was 0.50 +/- 0.18 mg/kg and protamine dosage was 57.14 +/- 39.36 mg. Postoperative blood loss and transfusion requirements were minimal. Postoperative complement levels of C3a and C5a were normal, suggesting excellent biocompatibility. There were no deaths or perioperative complications. Heparin-coated CPB circuits using a pump oxygenator can be used safely with low-dose heparin administration in select patients requiring CPB.
引用
收藏
页码:815 / 819
页数:5
相关论文
共 23 条
[1]   THROMBIN UPTAKE AND INHIBITION ON ENDOTHELIUM AND SURFACES WITH A STABLE HEPARIN COATING - A COMPARATIVE INVITRO STUDY [J].
ARNANDER, C ;
DRYJSKI, M ;
LARSSON, R ;
OLSSON, P ;
SWEDENBORG, J .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1986, 20 (02) :235-246
[2]   INFLUENCE OF BLOOD-FLOW AND THE EFFECT OF PROTAMINE ON THE THROMBORESISTANT PROPERTIES OF A COVALENTLY BONDED HEPARIN SURFACE [J].
ARNANDER, C ;
OLSSON, P ;
LARM, O .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1988, 22 (10) :859-868
[3]  
BOROWIEC J, 1992, J THORAC CARDIOV SUR, V104, P642
[4]   HEPARIN-COATED CARDIOPULMONARY BYPASS CIRCUITS AND 25-PERCENT REDUCTION OF HEPARIN DOSE IN CORONARY-ARTERY SURGERY - A CLINICAL-STUDY [J].
BOROWIEC, J ;
THELIN, S ;
BAGGE, L ;
VANDERLINDEN, J ;
THORNO, E ;
HANSSON, HE .
UPSALA JOURNAL OF MEDICAL SCIENCES, 1992, 97 (01) :55-66
[5]   HEPARIN COATING REDUCES BLOOD-CELL ADHESION TO ARTERIAL FILTERS DURING CORONARY-BYPASS - A CLINICAL-STUDY [J].
BOROWIEC, JW ;
BYLOCK, A ;
VANDERLINDEN, J ;
THELIN, S .
ANNALS OF THORACIC SURGERY, 1993, 55 (06) :1540-1545
[6]   COMPLEMENT ACTIVATION DURING CARDIOPULMONARY BYPASS - EVIDENCE FOR GENERATION OF C3A AND C5A ANAPHYLATOXINS [J].
CHENOWETH, DE ;
COOPER, SW ;
HUGLI, TE ;
STEWART, RW ;
BLACKSTONE, EH ;
KIRKLIN, JW .
NEW ENGLAND JOURNAL OF MEDICINE, 1981, 304 (09) :497-503
[7]  
GOTT VL, 1963, SCIENCE, V142, P1297, DOI 10.1126/science.142.3597.1297
[8]   USE OF HEPARIN-COATED CARDIOPULMONARY BYPASS [J].
JONES, DR ;
HILL, RC ;
HOLLINGSED, MJ ;
STULLKEN, E ;
GRAEBER, GM ;
GUSTAFSON, RA ;
MURRAY, GF .
ANNALS OF THORACIC SURGERY, 1993, 56 (03) :556-558
[10]  
KIRKLIN JK, 1983, J THORAC CARDIOV SUR, V86, P845