RECYCLING NEBULIZATION SYSTEM WITH EXCHANGEABLE SPRAY CHAMBER FOR INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY

被引:7
作者
ISOYAMA, H
UCHIDA, T
IIDA, C
NAKAGAWA, G
机构
[1] Department of Applied Chemistry, Nagoya Institute of Technology, Showa-ku, Nagoya, 466, Gokiso-cho
关键词
Exchangeable spray chamber; Inductively coupled plasma atomic emission spectrometry; Microwave sample decomposition; Recycling nebulisation system;
D O I
10.1039/ja9900500365
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A recycling nebulisation system with a small exchangeable spray chamber was developed for inductively coupled plasma atomic emission spectrometry, allowing rapid exchange of samples without extinguishing the plasma. The exchange of the chamber required only 3 min with a memory effect of less than 0.01%. The proposed system allowed continuous nebulisation for 30 min with 2 ml of sample, but a gradual increase in the signal was observed owing to the enrichment of determinants. This signal drift was almost cancelled out in sequential measurements, because the elements were measured in the same sequence for both samples and standards. The system was successfully applied to the analysis of some certified reference materials.
引用
收藏
页码:365 / 369
页数:5
相关论文
共 11 条
[1]  
HE ZZ, 1985, SPECTROCHIM ACTA B, V40, P11
[2]   A PNEUMATIC RECIRCULATING NEBULIZER SYSTEM FOR SMALL SAMPLE VOLUMES [J].
HULMSTON, P .
ANALYST, 1983, 108 (1283) :166-170
[3]   SMALL SPRAY CHAMBER WITH A CONCENTRIC NEBULIZER FOR INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
ISOYAMA, H ;
UCHIDA, T ;
IIDA, C ;
NAKAGAWA, G .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1990, 5 (04) :307-310
[4]   SMALL SPRAY CHAMBER FOR INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY AND ITS EVALUATION BY A DIGITAL SIGNAL SAMPLING TECHNIQUE [J].
ISOYAMA, H ;
UCHIDA, T ;
NIWA, T ;
IIDA, C ;
NAKAGAWA, G .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (04) :351-355
[5]   DETERMINATION OF TRACE-METALS IN BIOLOGICAL SAMPLES BY INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY WITH DISCRETE NEBULIZATION AFTER MICROWAVE DECOMPOSITION [J].
ISOYAMA, H ;
UCHIDA, T ;
OGUCHI, K ;
IIDA, C ;
NAKAGAWA, G .
ANALYTICAL SCIENCES, 1990, 6 (03) :385-388
[6]   RECYCLING NEBULIZATION-SAMPLE INTRODUCTION SYSTEM FOR INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
KATO, K ;
TAKASHIMA, K .
ANALYTICAL SCIENCES, 1989, 5 (02) :151-156
[7]  
KOJIMA I, 1988, ANAL SCI, V4, P2211
[8]   FIXED CROSS-FLOW NEBULIZER FOR USE WITH INDUCTIVELY COUPLED PLASMAS AND FLAMES [J].
NOVAK, JW ;
LILLIE, DE ;
BOORN, AW ;
BROWNER, RF .
ANALYTICAL CHEMISTRY, 1980, 52 (03) :576-579
[10]   EVALUATION OF RECYCLING CYCLONE SPRAY CHAMBERS FOR ICP-AES [J].
VIEIRA, PA ;
ZHIZHUANG, H ;
CHAN, SK ;
MONTASER, A .
APPLIED SPECTROSCOPY, 1986, 40 (08) :1141-1146