EFFECT OF SUCTION ON SPECIMEN SIZE IN FINE-NEEDLE ASPIRATION BIOPSY

被引:23
作者
KREULA, J
VIRKKUNEN, P
BONDESTAM, S
机构
[1] UNIV HELSINKI,CENT HOSP,DEPT DIAGNOST RADIOL,HAARTMANINKATU 4,SF-00290 HELSINKI 29,FINLAND
[2] UNIV HELSINKI,CENT HOSP,DEPT RADIOTHERAPY & ONCOL,SF-00290 HELSINKI 29,FINLAND
关键词
Biopsy; Needle; Sampling technique; Specimen size;
D O I
10.1097/00004424-199011000-00005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
High incidences of unsatisfactory specimens in fine-needle aspiration biopsy for cytology have been reported previously. Inappropriate aspiration techniques may account partly for this. In this study, the effect of suction on specimen size was studied in vitro using an automatic sampler. Bovine liver, testis, and pig's kidney were used as target tissues and biopsies were performed with 18-, 20- and 22-gauge needles. Specimen weight increased rapidly and linearly with suction force (P <.001), regardless of the target tissue or needle diameter, when standard needle movement was applied. In the absence of needle movement, the suction force, rate of increase of suction, and duration of suction had no effect on the weight of the specimens. Needle movement alone, without suction, also produced meager specimens. Suction alone does not seem to tear fragments off target tissues. Nevertheless, in combination with needle movement, suction force plays an important role in the determination of specimen size. © Lippincott-Raven Publishers.
引用
收藏
页码:1175 / 1181
页数:7
相关论文
共 23 条
[1]  
AARDAL N-P, 1989, Tidsskrift for den Norske Laegeforening, V109, P2284
[2]  
ABELE JS, 1983, ARCH SURG-CHICAGO, V118, P859
[3]   PERCUTANEOUS BIOPSY [J].
BERNARDINO, ME .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 142 (01) :41-45
[4]   PREOPERATIVE DIAGNOSIS IN CARCINOMA OF BREAST [J].
DAVIES, CJ ;
ELSTON, CW ;
COTTON, RE ;
BLAMEY, RW .
BRITISH JOURNAL OF SURGERY, 1977, 64 (05) :326-328
[5]  
DIXON JM, 1983, LANCET, V2, P564
[6]   FINE NEEDLE ASPIRATION CYTOLOGY, IN RELATIONSHIPS TO CLINICAL EXAMINATION AND MAMMOGRAPHY IN THE DIAGNOSIS OF A SOLID BREAST MASS [J].
DIXON, JM ;
ANDERSON, TJ ;
LAMB, J ;
NIXON, SJ ;
FORREST, APM .
BRITISH JOURNAL OF SURGERY, 1984, 71 (08) :593-596
[7]   FINE-NEEDLE ASPIRATION BIOPSY - A REVIEW [J].
FRABLE, WJ .
HUMAN PATHOLOGY, 1983, 14 (01) :9-28
[8]  
FURNIVAL CM, 1975, LANCET, V2, P446
[9]   GUIDED PERCUTANEOUS BIOPSY OF INTRAABDOMINAL LESIONS [J].
GAZELLE, GS ;
HAAGA, JR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (05) :929-935
[10]  
Glant M D, 1984, Indiana Med, V77, P595