CALIBRATION OF THE FISSION-TRACK DATING METHOD - IS CU USEFUL AS AN ABSOLUTE THERMAL-NEUTRON FLUENCE MONITOR

被引:22
作者
DECORTE, F [1 ]
VANDENHAUTE, P [1 ]
DEWISPELAERE, A [1 ]
JONCKHEERE, R [1 ]
机构
[1] STATE UNIV GHENT,INST GEOL,B-9000 GHENT,BELGIUM
关键词
D O I
10.1016/0168-9622(91)90048-2
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
Thermal neutron fluence measurements have been performed with Au and Co standard monitors at the one side and Cu monitors (foils and wires) at the other, using three reactor channels with different neutron energy spectra and two calibrated Ge detectors. Care was taken to eliminate errors caused by epithermal activation and neutron self-shielding while special attention was also paid to the problem of incomplete annihilation of the Cu-64-beta+ radiation. Our new measurements reveal consistent fluences between Cu and the Au and Co standard monitors, when using the recommended and/or recently evaluated nuclear parameters for the Cu-63(n,gamma)Cu-64 reaction. However, we do not endorse the usage of Cu as a standard fluence monitor for fission-track dating because from a metrological standpoint too large uncertainties still exist on some of its relevant nuclear parameters such as the thermal neutron activation cross-section (sigma-0) of Cu-63.
引用
收藏
页码:187 / 194
页数:8
相关论文
共 32 条
[1]  
Andersson P., 1986, Nuclear Data Sheets, V48, P251, DOI 10.1016/S0090-3752(86)80110-7
[2]  
BAUMANN NP, 1963, DP817 AT EN COMM RES
[3]  
BECKURTS KH, 1964, NEUTRON PHYSICS
[4]  
CARPENTER BS, 1974, NBS26049 SPEC PUBL
[5]  
CARPENTER BS, 1984, NBS26092 SPEC PUBL
[6]   THE DECAY SCHEME OF CU-64 [J].
CHRISTMAS, P ;
JUDGE, SM ;
RYVES, TB ;
SMITH, D ;
WINKLER, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 215 (03) :397-408
[7]  
DEBEECK JO, 1976, DESCRIPTION STRUCTUR
[8]   TABLE OF THE ISOTOPIC COMPOSITION OF THE ELEMENTS AS DETERMINED BY MASS-SPECTROMETRY [J].
DEBIEVRE, P ;
BARNES, IL .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1985, 65 (1-2) :211-230
[9]   ACCURACY AND APPLICABILITY OF THE K0-STANDARDIZATION METHOD [J].
DECORTE, F ;
SIMONITS, A ;
DEWISPELAERE, A ;
HOSTE, J .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1987, 113 (01) :145-161
[10]   APPLICABILITY OF THE 1/E1+ALPHA-EPITHERMAL SPECTRUM REPRESENTATION AND THE EFFECTIVE RESONANCE ENERGY ER IN NAA [J].
DECORTE, F ;
MOENS, L ;
JOVANOVIC, S ;
SIMONITS, A ;
DEWISPELAERE, A .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1986, 102 (01) :37-57