GADOLINIUM-DTPA (MAGNEVIST) AS A CONTRAST-MEDIUM FOR ARTERIAL DSA

被引:34
作者
SCHILD, HH
WEBER, W
BOECK, E
MILDENBERGER, P
STRUNK, H
DUBER, C
GREBE, P
SCHADMANDFISCHER, S
THELEN, M
机构
来源
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN | 1994年 / 160卷 / 03期
关键词
DSA; CONTRAST MEDIUM; GADOLINIUM-DTPA; IA ADMINISTRATION; SIDE EFFECTS;
D O I
10.1055/s-2008-1032410
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
16 DSA investigations using intra-arterial Gd-DTPA were performed on 12 patients. The contrast medium was administered either as a 0.5 molar gadolinium solution (commercially available) or diluted with distilled water to a 0.2 - 0.4 molar gadolinium solution. The injection was made either by pressure injector or by hand. The aortic arch, abdominal aorta and pelvic and lower limb arteries were examined. 14 of the 16 procedures were diagnostically adequate, but compared with iodinated contrast materials, contrast was less marked. There were no cardiovascular, neurological or allergic side effects. Three patients suffered a feeling of heat and one patient had mild pain during the injection. Even large volumes rapidly injected (up to 20 ml/s of the commercially available solution) were well tolerated. DSA with intra-arterial Gd-DTPA seems to be a suitable alternative for vascular imaging if iodine-containing contrast materials are contraindicated.
引用
收藏
页码:218 / 221
页数:4
相关论文
共 13 条
  • [1] THE CEREBROVASCULAR EFFECTS OF INTRAARTERIAL CO2 IN QUANTITIES REQUIRED FOR DIAGNOSTIC-IMAGING
    COFFEY, R
    QUISLING, RG
    MICKLE, JP
    HAWKINS, IF
    BALLINGER, WB
    [J]. RADIOLOGY, 1984, 151 (02) : 405 - 410
  • [2] HAUSTEIN J, 1991, RADIOLOGY, V181, P113
  • [3] KASHANIAN FK, 1990, AM J NEURORADIOL, V11, P853
  • [4] ADVERSE REACTIONS TO IONIC AND NONIONIC CONTRAST-MEDIA - A REPORT FROM THE JAPANESE-COMMITTEE-ON-THE-SAFETY-OF-CONTRAST MEDIA
    KATAYAMA, H
    YAMAGUCHI, K
    KOZUKA, T
    TAKASHIMA, T
    SEEZ, P
    MATSUURA, K
    [J]. RADIOLOGY, 1990, 175 (03) : 621 - 628
  • [5] KRASNY R, 1987, FORTSCHR RONTG NEUEN, V146, P450
  • [6] CARDIOVASCULAR-RESPONSES AFTER IONIC AND NONIONIC MAGNETIC-RESONANCE CONTRAST-MEDIA IN RATS WITH ACUTE MYOCARDIAL-INFARCTION
    LI, HT
    SAEED, M
    WENDLAND, MF
    HIGGINS, CB
    [J]. INVESTIGATIVE RADIOLOGY, 1993, 28 (01) : 11 - 19
  • [7] Niendorf H. P., 1990, CONTRAST MEDIA MRI, P31
  • [8] ANGIOGRAPHY VIA AN ATOMIZER - A NOVEL TECHNIQUE OF ARTERIAL IMAGING WITH CO2 UNDER DSA CONDITIONS
    SCHMITZRODE, T
    ALZEN, G
    GUNTHER, RW
    [J]. FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1993, 159 (01): : 97 - 99
  • [9] HEMODYNAMIC-EFFECTS OF RAPID AND SLOW INFUSIONS OF MANGANESE CHLORIDE AND GADOLINIUM-DTPA IN DOGS
    SLUTSKY, RA
    PETERSON, T
    STRICH, G
    BROWN, JJ
    [J]. RADIOLOGY, 1985, 154 (03) : 733 - 735
  • [10] ARTERIAL INTERVENTIONAL MEASURES USING CARBON-DIOXIDE (CO2) AS CONTRAST-MEDIUM
    STRUNK, H
    SCHILD, H
    MORTASAWI, MA
    [J]. FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1992, 157 (06): : 599 - 600