LIMITATIONS OF BALLOON ANGIOPLASTY FOR VEIN GRAFT STENOSIS

被引:63
作者
WHITTEMORE, AD
DONALDSON, MC
POLAK, JF
MANNICK, JA
机构
[1] BRIGHAM & WOMENS HOSP, DEPT RADIOL, BOSTON, MA 02115 USA
[2] HARVARD UNIV, SCH MED, BOSTON, MA 02115 USA
关键词
D O I
10.1016/0741-5214(91)90086-A
中图分类号
R61 [外科手术学];
学科分类号
摘要
Vein graft stenosis remains an important contributing factor to the failure of infrainguinal arterial reconstruction. Repair of these lesions before graft occlusion provides sustained patency, yet the optimal method of repair has not been established. Percutaneous transluminal balloon angioplasty of these vein graft lesions has been repeatedly advocated as an alternative to surgical revision. Balloon angioplasty was used in 30 patients with 54 stenotic lesions occurring in autogenous vein grafts after infrainguinal reconstruction. The primary 5-year cumulative patency rate was 18% overall, with no significant differences observed among patency rates based on initial indication, length of stenotic lesion, or requirement for preliminary thrombolytic therapy. The 3-year patency rate associated with vein graft lesions requiring only a single angioplasty proved significantly higher (59%) than those requiring repetitive dilations (6%). It is our conclusion that balloon angioplasty for vein graft stenosis has significant limitations in providing sustained secondary patency.
引用
收藏
页码:340 / 345
页数:6
相关论文
共 16 条
[1]   TREATMENT OF VEIN GRAFT STENOSIS BY BALLOON CATHETER DILATION [J].
ALPERT, JR ;
RING, EJ ;
BERKOWITZ, HD ;
FREIMAN, DB ;
OLEAGA, JA ;
GORDON, R ;
ROBERTS, B .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1979, 242 (25) :2769-2771
[2]   DURABILITY OF VEIN GRAFT REVISION - THE OUTCOME OF SECONDARY PROCEDURES [J].
BANDYK, DF ;
BERGAMINI, TM ;
TOWNE, JB ;
SCHMITT, DD ;
SEABROOK, GR .
JOURNAL OF VASCULAR SURGERY, 1991, 13 (02) :200-210
[3]   OBSERVATIONS ON THE USE OF THROMBOLYTIC AGENTS FOR THROMBOTIC OCCLUSION OF INFRAINGUINAL VEIN GRAFTS [J].
BELKIN, M ;
DONALDSON, MC ;
WHITTEMORE, AD ;
POLAK, JF ;
GRASSI, CJ ;
HARRINGTON, DP ;
MANNICK, JA .
JOURNAL OF VASCULAR SURGERY, 1990, 11 (02) :289-296
[4]  
BREWSTER DC, 1983, ARCH SURG-CHICAGO, V118, P1043
[5]  
COHEN JR, 1986, ARCH SURG-CHICAGO, V121, P758
[6]  
GREENSPAN B, 1985, ARCH SURG-CHICAGO, V120, P492
[7]  
MANTEL NATHAN, 1966, CANCERCHEMOTHERAP REP, V50, P163
[8]  
PERLER BA, 1990, J CARDIOVASC SURG, V31, P656
[9]   EARLY DETECTION OF SAPHENOUS-VEIN ARTERIAL BYPASS GRAFT STENOSIS BY COLOR-ASSISTED DUPLEX SONOGRAPHY - A PROSPECTIVE-STUDY [J].
POLAK, JF ;
DONALDSON, MC ;
DOBKIN, GR ;
MANNICK, JA ;
OLEARY, DH .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (04) :857-861
[10]   EARLY EXPERIENCE WITH PERCUTANEOUS TRANS-LUMINAL ANGIOPLASTY USING A VINYL BALLOON CATHETER [J].
RING, EJ ;
ALPERT, JR ;
FREIMAN, DB ;
OLEAGA, JA ;
BERKOWITZ, H ;
ROBERTS, B .
ANNALS OF SURGERY, 1980, 191 (04) :438-442