NONINVASIVE LOCALIZATION OF ARTERIAL OCCLUSIVE DISEASE - A COMPARISON OF SEGMENTAL DOPPLER PRESSURES AND ARTERIAL DUPLEX MAPPING

被引:51
作者
MONETA, GL
YEAGER, RA
LEE, RW
PORTER, JM
机构
[1] OREGON HLTH SCI UNIV, DEPT RADIOL, PORTLAND, OR 97201 USA
[2] VET AFFAIRS MED CTR, PORTLAND, OR USA
关键词
D O I
10.1016/0741-5214(93)90158-I
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: The purpose of this study was to compare the abilities of arterial duplex mapping and segmental Doppler pressures to noninvasively localize hemodynamically significant lower extremity arterial occlusive disease. Methods: After angiographic controls were instituted, arterial duplex mapping and segmental Doppler pressures were blindly compared for their ability to localize a high-grade (50% to 100%) stenosis to the iliac or common femoral arteries, the superficial femoral artery, or the popliteal artery in 151 lower extremities from 79 patients. Results: Pates of sensitivity and specificity of arterial duplex mapping for identifying a high-grade stenosis at the three arterial levels were 88% and 97%, 95% and 100%, and 78% and 99%, respectively. Those for segmental Doppler pressures were 59% and 86%, 73% and 80%, and 48% and 53%, respectively. There was complete agreement between arterial duplex mapping and angiography in 82% of the limbs studied and between segmental pressures and angiography in 34% of the limbs (p < 0.0001). The presence of diabetes, kidney failure, or previous vascular surgery in the limb studied did not affect the accuracy of either test. Conclusion: Arterial duplex mapping is far superior to segmental Doppler pressures for localization of high-grade angiographic lesions from the iliac to the popliteal arteries.
引用
收藏
页码:578 / 582
页数:5
相关论文
共 10 条
  • [1] BRIDGES RA, 1987, PRACTICAL NONINVASIV, P112
  • [2] CARTER SA, 1985, NONINVASIVE DIAGNOST, P513
  • [3] Caster JD, 1992, J VASCULAR TECHNOLOG, V16, P63
  • [4] COMPARISON OF CONTRAST ARTERIOGRAPHY TO ARTERIAL MAPPING WITH COLOR-FLOW DUPLEX IMAGING IN THE LOWER-EXTREMITIES
    COSSMAN, DV
    ELLISON, JE
    WAGNER, WH
    CARROLL, RM
    TREIMAN, RL
    FORAN, RF
    LEVIN, PM
    COHEN, JL
    [J]. JOURNAL OF VASCULAR SURGERY, 1989, 10 (05) : 522 - 529
  • [5] FLANIGAN DP, 1982, SURGERY, V92, P16
  • [6] GLAUTZ SA, 1987, PRIMER BIOSTATISTICS
  • [7] ASSESSMENT OF PRESSURE-GRADIENT BY DOPPLER ULTRASOUND - EXPERIMENTAL AND CLINICAL OBSERVATIONS
    KOHLER, TR
    NICHOLLS, SC
    ZIERLER, RE
    BEACH, KW
    SCHUBART, PJ
    STRANDNESS, DE
    [J]. JOURNAL OF VASCULAR SURGERY, 1987, 6 (05) : 460 - 469
  • [8] ACCURACY OF LOWER-EXTREMITY ARTERIAL DUPLEX MAPPING
    MONETA, GL
    YEAGER, RA
    ANTONOVIC, R
    HALL, LD
    CASTER, JD
    CUMMINGS, CA
    PORTER, JM
    [J]. JOURNAL OF VASCULAR SURGERY, 1992, 15 (02) : 275 - 284
  • [9] ROSENBLOOM MS, 1988, ARCH SURG-CHICAGO, V123, P867
  • [10] ANKLE SYSTOLIC PRESSURE MEASUREMENTS IN ARTERIAL DISEASE AFFECTING LOWER EXTREMITIES
    YAO, ST
    HOBBS, JT
    IRVINE, WT
    [J]. BRITISH JOURNAL OF SURGERY, 1969, 56 (09) : 676 - &