DIOXETANE CHEMILUMINESCENCE DETECTION IN LIQUID-CHROMATOGRAPHY BASED ON PHOTOSENSITIZED ONLINE GENERATION OF SINGLET MOLECULAR-OXYGEN - A THOROUGH EXAMINATION OF EXPERIMENTAL PARAMETERS AND APPLICATION TO POLYCHLORINATED-BIPHENYLS

被引:18
作者
NIEDERLANDER, HAG [1 ]
NUIJENS, MJ [1 ]
DOZY, EM [1 ]
GOOIJER, C [1 ]
VELTHORST, NH [1 ]
机构
[1] FREE UNIV AMSTERDAM,DEPT GEN & ANALYT CHEM,1081 HV AMSTERDAM,NETHERLANDS
关键词
CHEMILUMINESCENCE; LIQUID CHROMATOGRAPHY; DIOXETANES; ONLINE PHOTOCHEMICAL REACTION; PHOTOOXYGENATION; POLYCHLORINATED BIPHENYLS (PCBS); SINGLET MOLECULAR OXYGEN;
D O I
10.1016/0003-2670(94)00229-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Experimental parameters influencing sensitivity and selectivity in chemiluminescence detection based on photoinduced production of singlet molecular oxygen in liquid chromatography, an approach introduced in earlier papers, are extensively studied. Normal-phase liquid chromatography is applied in addition to reversed-phase chromatography, using polychlorinated biphenyls (PCBs) as analytes. The photochemical reactor parameters play the most important role. The chemiluminescence detector parameters are generally restrained by the required photochemical reactor conditions. An alternative, commercially available, reagent for addition of singlet molecular oxygen (i.e., ethyl vinyl ether) and a new photochemical reactor construction are introduced and compared to the former ones. The experiments show that the optimum conditions are strongly determined by the individual PCB concerned. Planar PCBs known for their high toxicity, such as the PCBs 77, 126 and 169 can be detected far more sensitively than the non-planar ones. The inherent selectivity of the method is shown for a herring oil sample, spiked with the above PCBs, utilizing normal-phase liquid chromatography with a pyrenyl column.
引用
收藏
页码:349 / 368
页数:20
相关论文
共 49 条
[1]  
Adam W., 1982, CHEM BIOL GENERATION
[2]   1.2-DAILKOXY-ATHENE .12. SYNTHESE VON 1.2-DIALKOXY-ATHENEN AUS 1.2-DICHLOR-1.2-DIALKOXY-ATHANEN [J].
BAGANZ, H ;
PRAEFCKE, K ;
ROST, J .
CHEMISCHE BERICHTE-RECUEIL, 1963, 96 (10) :2657-&
[3]   GAS CHROMATOGRAPHY-NEGATIVE ION CHEMICAL-IONIZATION MASS-SPECTROMETRY FOR THE DETERMINATION AND IDENTIFICATION OF PLANAR POLYCHLORINATED-BIPHENYLS IN BIOLOGICAL SAMPLES [J].
BAGHERI, H ;
LEONARDS, PEG ;
GHIJSEN, RT ;
BRINKMAN, UAT .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1993, 50 (04) :257-268
[4]   ANALYSIS OF POLYCHLORINATED-BIPHENYLS (PCB) BY GLASS-CAPILLARY GAS-CHROMATOGRAPHY - COMPOSITION OF TECHNICAL AROCLOR-PCB AND CLOPHEN-PCB MIXTURES [J].
BALLSCHMITER, K ;
ZELL, M .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1980, 302 (01) :20-31
[5]  
BARTLETT PD, 1979, SINGLET OXYGEN ORGAN, V40, P243
[6]   APPLICATIONS OF DIOXETANE CHEMILUMINESCENT PROBES TO MOLECULAR-BIOLOGY [J].
BECK, S ;
KOSTER, H .
ANALYTICAL CHEMISTRY, 1990, 62 (21) :2258-2270
[7]   2 WATER-SOLUBLE FLUORESCENCE PROBES FOR CHEMIEXCITATION STUDIES - SODIUM 9,10-DIBROMO-ANTHRACENE-2-SULFONATE AND 9,10-DIPHENYLANTHRACENE-2-SULFONATE - SYNTHESIS, PROPERTIES AND APPLICATION TO TRIPLET ACETONE AND TETRAMETHYLDIOXETANE [J].
CATALANI, LH ;
WILSON, T ;
BECHARA, EJH .
PHOTOCHEMISTRY AND PHOTOBIOLOGY, 1987, 45 (02) :273-281
[8]   SENSITIZED ROOM-TEMPERATURE PHOSPHORESCENCE FOR DETECTION IN CONTINUOUS-FLOW AND CHROMATOGRAPHIC SYSTEMS [J].
DONKERBROEK, JJ ;
HOMMES, NJRV ;
GOOIJER, C ;
VELTHORST, NH ;
FREI, RW .
CHROMATOGRAPHIA, 1982, 15 (04) :218-222
[9]   PHOSPHORESCENCE DETECTION OF POLYCHLORONAPHTHALENES AND POLYCHLOROBIPHENYLS IN LIQUID-CHROMATOGRAPHY [J].
DONKERBROEK, JJ ;
HOMMES, NJRV ;
GOOIJER, C ;
VELTHORST, NH ;
FREI, RW .
JOURNAL OF CHROMATOGRAPHY, 1983, 255 (JAN) :581-590
[10]   MULTIDIMENSIONAL GAS-CHROMATOGRAPHY WITH ELECTRON-CAPTURE DETECTION FOR THE DETERMINATION OF TOXIC CONGENERS IN POLYCHLORINATED BIPHENYL MIXTURES [J].
DUINKER, JC ;
SCHULZ, DE ;
PETRICK, G .
ANALYTICAL CHEMISTRY, 1988, 60 (05) :478-482