AN AUTOMATIC METHOD FOR BONE HISTOMORPHOMETRY - ASSESSMENT WITH REFERENCE TO USUAL STATIC AND DYNAMIC PARAMETERS

被引:16
作者
JUVIN, R [1 ]
CAMUS, E [1 ]
USSON, Y [1 ]
PHELIP, X [1 ]
机构
[1] UNIV JOSEPH FOURIER,TIM LAB 3,CNRS,UA 397,GRENOBLE,FRANCE
关键词
D O I
10.1002/jbmr.5650050306
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To perform a fast and reproducible analysis in bone histomorphometry, we developed an automatic method for calculating static and dynamic parameters. A color automatic image analyzer (SAMBA 200) was used to obtain the usual parameters of bone histomorphometry: bone volume (Cn‐BV%TV), osteoid volume (Cn‐OV%BV), and osteoid surface (Cn‐OS%BS). A specialized algorithm was designed for calculation of the mineral apposition rate (MAR). Eroded surface (Cn‐ES%BS) was read in a semiautomatic mode using a cursor. To validate this program, we input 30 samples from patients with bone disease (20 osteoporosis, 6 renal osteodystrophy, 2 osteomalacia, and 2 hyperparathyroidism) using manual and automatic modes. The results obtained showed a highly significant correlation with the usual manual method for all parameters: OS/BS, r = 0.93; OV/BV, r = 0.98; MAR, r = 0.90. With the automatic method, larger values were found for osteoid parameters and MAR and lower values for BV/TV. There were no statistical differences for OV/BV and MAR when compared to the reference manual method. This study establishes that automatic measurements of osteoid parameters and MAR can be performed by a fast analyzer with as good reproducibility and accuracy as the manual method. Copyright © 1990 ASBMR
引用
收藏
页码:235 / 244
页数:10
相关论文
共 18 条
[1]  
BEISBEDER M, 1988, J MICROSC, V150, P151
[2]  
Birkenhager-Frenkel DH., 1976, BONE HISTOMORPHOMETR, P63
[3]  
BRUGAL G, 1986, METHODS ACHIEV EXP P, V11, P1
[4]   INTERMETHOD VARIATION IN BONE HISTOMORPHOMETRY - COMPARISON BETWEEN MANUAL AND COMPUTERIZED METHODS APPLIED TO ILIAC BONE BIOPSIES [J].
CHAVASSIEUX, PM ;
ARLOT, ME ;
MEUNIER, PJ .
BONE, 1985, 6 (04) :221-229
[5]   INTEROBSERVER AND INTRAOBSERVER VARIATION IN BONE HISTOMORPHOMETRY [J].
COMPSTON, JE ;
VEDI, S ;
STELLON, AJ .
CALCIFIED TISSUE INTERNATIONAL, 1986, 38 (02) :67-70
[6]  
DELLING G, 1980, BONE HISTOMORPHOMETR, P419
[7]   BONE HISTOMORPHOMETRIC REPRODUCIBILITY IN NORMAL-PATIENTS [J].
DEVERNEJOUL, M ;
KUNTZ, D ;
MIRAVET, L ;
GOUTALLIER, D ;
RYCKEWAERT, A .
CALCIFIED TISSUE INTERNATIONAL, 1981, 33 (04) :369-374
[8]   TETRACYCLINE-BASED HISTOLOGICAL ANALYSIS OF BONE REMODELING [J].
FROST, HM .
CALCIFIED TISSUE RESEARCH, 1969, 3 (03) :211-&
[9]  
FROST HM, 1983, HISTOMORPHOMETRY TEC, P109
[10]  
GARBAY C, 1981, ANAL QUANT CYTOL, V3, P272