THE EVALUATION OF A TENAX GR DIFFUSIVE SAMPLER FOR THE DETERMINATION OF BENZENE AND OTHER VOLATILE AROMATICS IN OUTDOOR AIR

被引:18
作者
GELENCSER, A
KISS, G
HLAVAY, J
HAFKENSCHEID, TL
PETERS, RJB
DELEER, EWB
机构
[1] TNO,INST ENVIRONM SCI,POB 6011,2600 JA DELFT,NETHERLANDS
[2] UNIV VESZPREM,H-8201 VESZPREM,HUNGARY
关键词
D O I
10.1016/0039-9140(94)80077-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The applicability of a tube-type diffusive sampler as an environmental monitor for benzene, toluene, ethylbenzene and xylene (BTEX) is reported. Uptake rates have been experimentally determined for a novel type adsorbent, Tenax GR, and compared to theoretical values. It is shown, that the uptake rates are virtually independent of environmental parameters within the experimental conditions studied. The response of the sampler to transient changes in concentrations has been determined in the laboratory. It is found that the sampler is capable of following an extreme concentration profile. Field comparisons with pumped samplers have been performed and good agreement is observed between the results of the two independent methods. The samplers have also been applied as environmental monitors at different locations.
引用
收藏
页码:1095 / 1100
页数:6
相关论文
共 13 条
[1]  
BERLIN A, 1987, CEC1055EN PUBL
[2]   THE DEVELOPMENT OF AN IMPROVED DIFFUSIVE SAMPLER [J].
BROWN, RH ;
CHARLTON, J ;
SAUNDERS, KJ .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1981, 42 (12) :865-869
[3]  
BROWN RH, IN PRESS PURE APPL C
[4]   DIFFUSIVE SAMPLING - A REVIEW [J].
HARPER, M ;
PURNELL, CJ .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1987, 48 (03) :214-218
[5]  
KRISTENSON J, COMMUNICATION
[6]   DIFFUSION COEFFICIENTS OF SOME ORGANIC AND OTHER VAPORS IN AIR [J].
LUGG, GA .
ANALYTICAL CHEMISTRY, 1968, 40 (07) :1072-&
[7]  
SAUNDERS K, COMMUNICATION
[8]  
VANDENHOED N, 1987, AM IND HYG ASSOC J, V48, P364, DOI 10.1202/0002-8894(1987)048<0364:SATDEO>2.0.CO
[9]  
2
[10]  
Wright M, COMMUNICATION