LOCAL BLOOD-VOLUME CHANGES IN WOMEN WITH PELVIC CONGESTION MEASURED BY APPLIED POTENTIAL TOMOGRAPHY

被引:12
作者
THOMAS, DC [1 ]
MCARDLE, FJ [1 ]
ROGERS, VE [1 ]
BEARD, RW [1 ]
BROWN, BH [1 ]
机构
[1] UNIV SHEFFIELD, DEPT MED PHYS & CLIN ENGN, SHEFFIELD S10 2TN, S YORKSHIRE, ENGLAND
关键词
APPLIED POTENTIAL TOMOGRAPHY; BLOOD VOLUME; PELVIC CONGESTION; PELVIS; POSTURE;
D O I
10.1042/cs0810401
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
1. Applied potential tomography is a new, non-invasive technology for observing changes in blood volume. We have used it to study 12 women with lower abdominal pain caused by pelvic congestion, and 15 control subjects. 2. A significant increase in blood volume of 1.8% was observed in the pelvis of women with congestion when changing from the supine to the erect position, and of 2.7% in the control subjects (P < 0.0002). The difference between the groups was not significant. 3. The distribution of the area over which blood volume changes took place was significantly different between the two groups (P < 0.002). More of the posterolateral part of the pelvis was involved in women with pelvic congestion than in the control subjects. 4. Applied potential tomography distinguishes between normal women and those having pelvic congestion with a specificity of 87% and a sensitivity of 75%.
引用
收藏
页码:401 / 404
页数:4
相关论文
共 8 条
[1]   CLINICAL-FEATURES OF WOMEN WITH CHRONIC LOWER ABDOMINAL-PAIN AND PELVIC CONGESTION [J].
BEARD, RW ;
REGINALD, PW ;
WADSWORTH, J .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1988, 95 (02) :153-161
[2]  
BEARD RW, 1984, LANCET, V2, P946
[3]   DETERMINATION OF UPPER ARM MUSCLE AND FAT AREAS USING ELECTRICAL-IMPEDANCE MEASUREMENTS [J].
BROWN, BH ;
KARATZAS, T ;
NAKIELNY, R ;
CLARKE, RG .
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1988, 9 (01) :47-55
[4]  
EYUBOGLU BM, 1989, 11TH P ANN C IEEE EM, P442
[5]  
GONZALEZ RC, 1987, DIGITAL IMAGE PROCES, P246
[6]  
Lamont G L, 1988, Clin Phys Physiol Meas, V9 Suppl A, P65, DOI 10.1088/0143-0815/9/4A/012
[7]  
REGINALD PW, 1987, LANCET, V2, P351
[8]   ELECTRICAL-IMPEDANCE IMAGING [J].
SEAGAR, AD ;
BARBER, DC ;
BROWN, BH .
IEE PROCEEDINGS-A-SCIENCE MEASUREMENT AND TECHNOLOGY, 1987, 134 (02) :201-210