AN ANALOG-TO-DIGITIAL CONVERSION BASED ON A MOVING WINDOW DECONVOLUTION

被引:74
作者
GEORGIEV, A [1 ]
GAST, W [1 ]
LIEDER, RM [1 ]
机构
[1] INST NUCL ENERGY RES,SOFIA,BULGARIA
关键词
D O I
10.1109/23.322868
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 [电气工程]; 0809 [电子科学与技术];
摘要
A high-performance analog-to-digital conversion technique for nuclear spectroscopy applications with unconventional architecture is described. This technique is planned to be used in Phase III of the European gamma-ray facility project EUROBALL. The conversion is based on the Moving Window Deconvolution (MWD) method for signal processing in nuclear spectroscopy which has been introduced recently. This method allows the conversion to be represented as a sequence of measurements of the total charge of the event and consequently, by applying for example a simple oversampling scheme to achieve a high accuracy. The proposed MWD-type conversion exhibits very low differential and integral nonlinearities over a 14-bit resolution range with an effective conversion dead-time virtually zero. The last feature combined with an inherent pipeline conversion structure is of great importance for applications in large-scale multi-detector arrays like EUROBALL. The key parameters of the development have been theoretically estimated and measured with a prototype consisting of a free running A/D converter and a digital signal processor.
引用
收藏
页码:1116 / 1124
页数:9
相关论文
共 13 条
[1]
HARDWARE OVERVIEW OF THE EUROGAM DATA ACQUISITION-SYSTEM [J].
ALEXANDER, J ;
BECK, FA ;
ENDER, C ;
LAZARUS, I ;
MCPHERSON, GM ;
OWEN, ECG ;
POUXE, J ;
RICHARD, A ;
RING, C .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (04) :886-891
[2]
A HIGH-PERFORMANCE PEAK-DETECT AND HOLD CIRCUIT FOR PULSE-HEIGHT ANALYSIS [J].
BUCKENS, PF ;
VEATCH, MS .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (04) :753-757
[3]
FUZZY COARSE CODING UP-GRADES A/D CONVERTERS FOR PULSE-HEIGHT ANALYSIS [J].
CASOLI, P ;
MARANESI, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 205 (1-2) :167-171
[4]
AN ANALOG-TO-DIGITAL CONVERTER MODULE FOR NUCLEAR SPECTROMETRY [J].
CORREIA, CBA ;
CONDE, CAN .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 235 (03) :536-541
[5]
A NEW METHOD FOR ANALOG TO DIGITAL CONVERSION [J].
COTTINI, C ;
GATTI, E ;
SVELTO, V .
NUCLEAR INSTRUMENTS & METHODS, 1963, 24 (02) :241-242
[6]
DIGITAL PULSE PROCESSING IN HIGH-RESOLUTION, HIGH-THROUGHPUT GAMMA-RAY SPECTROSCOPY [J].
GEORGIEV, A ;
GAST, W .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) :770-779
[7]
Gerl J., 1992, EUROBALL 3 EUROPEAN
[8]
ULTRA-LINEAR, 14-BIT SPECTROSCOPY ADC [J].
GIANGANO, DA ;
KESSELMAN, M ;
CELONA, AR ;
BOCSKOR, SJ ;
SCHNEID, EJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) :398-402
[9]
PULSE-SHAPING IN LOW-NOISE NUCLEAR AMPLIFIERS - PHYSICAL APPROACH TO NOISE-ANALYSIS [J].
GOULDING, FS .
NUCLEAR INSTRUMENTS & METHODS, 1972, 100 (03) :493-&
[10]
HEUTS G, 1993, THESIS