SIMULTANEOUS QUANTIFICATION OF CYCLOSPORINE-A AND ITS MAJOR METABOLITES BY TIME-OF-FLIGHT SECONDARY-ION MASS-SPECTROMETRY AND MATRIX-ASSISTED LASER DESORPTION/IONIZATION MASS-SPECTROMETRY UTILIZING DATA-ANALYSIS TECHNIQUES - COMPARISON WITH HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

被引:39
作者
MUDDIMAN, DC
GUSEV, AI
STOPPEKLANGNER, K
PROCTOR, A
HERCULES, DM
TATA, P
VENKATARAMANAN, R
DIVEN, W
机构
[1] UNIV PITTSBURGH,DEPT CHEM,PITTSBURGH,PA 15260
[2] UNIV PITTSBURGH,DEPT PHARMACEUT SCI,PITTSBURGH,PA 15213
[3] UNIV PITTSBURGH,DEPT PATHOL,PITTSBURGH,PA 15213
来源
JOURNAL OF MASS SPECTROMETRY | 1995年 / 30卷 / 10期
关键词
D O I
10.1002/jms.1190301013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Simultaneous quantification of cyclosporin A (CsA) and its major metabolite (AM1) in blood has been achieved using time-of-flight secondary-ion mass spectrometry (TOF-SIMS) and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI/TOF-MS). Previous investigations indicated that spectral interferences exist in the analysis of CsA blood samples by the above methods, In TOF-SIMS, interference is caused by overlap of the Ag-cationized internal standard, cyclosporin D (CsD), with the Ag-cationized metabolite, AM1. To resolve this interference and obtain quantitative information, cross-correlation analysis was applied to the TOF-SIMS data, Application of damped non-linear least squares curve-fitting was carried out to resolve an interference in the MALDI/TOF-MS data due to multiple cationization products (i.e. Na and K), Measurement of standard samples indicates that the minimum accuracy (95% confidence level) of the TOF-SIMS method was better than 9% for CsA and 13% for AM1 using only one standard curve. Similarly, the minimum accuracy of the MALDI/TOF-MS method was determined to be 14% for CsA and better than 25% for AM1. Blood samples obtained from transplant patients receiving CsA were analyzed by polyclonal fluorescence polarization immunoassay, highperformance liquid chromatography (HPLC), and by both TOF-MS methods, Both TOF-MS results for CsA and mono-hydroxylated CsA are in good agreement with the HPLC results.
引用
收藏
页码:1469 / 1479
页数:11
相关论文
共 47 条
[1]  
ABECASSIS M, 1988, CAN J SURG, V31, P145
[2]   THERMOSPRAY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRIC DETERMINATION OF CYCLOSPORINS [J].
ABIAN, J ;
STONE, A ;
MORROW, MG ;
CREER, MH ;
FINK, LM ;
LAY, JO .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1992, 6 (11) :684-689
[3]  
BLICK KE, 1990, CLIN CHEM, V36, P670
[4]  
BOWERS LD, 1990, CLIN CHEM, V36, P1875
[5]  
BOWERS LD, 1990, BIOMED ENVIRON MASS, V17, P274
[6]  
BURCKART G, 1985, TRANSPLANT P, V17, P1172
[7]  
BURCKART GJ, 1986, TRANSPLANT P, V18, P188
[8]  
BURCKART GJ, 1986, TRANSPLANT P, V18, P129
[9]  
BURCKART GJ, 1990, TRANSPLANT P, V22, P1319
[10]  
CHEUNG F, 1988, TRANSPLANT P, V20, P602