DROPLETS PRODUCED BY MEDICAL NEBULIZERS - SOME FACTORS AFFECTING THEIR SIZE AND SOLUTE CONCENTRATION

被引:104
作者
PHIPPS, PR
GONDA, I
机构
关键词
D O I
10.1378/chest.97.6.1327
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The effect of nebulizer solution temperature and dilution air humidity on the size and solute concentration of aqueous aerosol droplets were studied. Four combinations of jet-nebulizers with air compressors or oxygen sources and one ultrasonic nebulizer were tested. The temperature to which the nebulizer solution of each system fell during generation was measured. The nebulizers were then kept at set temperatures, generated aerosols collected and either droplet size or solute concentration measured. The droplet solute concentration was found to increase. The droplet size decreased along with the droplet solute concentration increase. The ultrasonic nebulizer also was tested: its high output made the concentration of the solution in the droplets much more stable. However, the proportion of droplets depositing in the tubing and valves changed markedly with aerosol flow rate. The potential for large changes in droplet solute concentration, droplet size and output during nebulization should be considered in therapeutic and diagnostic applications of nebulized aerosols.
引用
收藏
页码:1327 / 1332
页数:6
相关论文
共 29 条
[1]   EVALUATION OF ULTRASONICALLY NEBULIZED SOLUTIONS FOR PROVOCATION TESTING IN PATIENTS WITH ASTHMA [J].
ANDERSON, SD ;
SCHOEFFEL, RE ;
FINNEY, M .
THORAX, 1983, 38 (04) :284-291
[2]   EFFECT OF NEBULIZED AEROSOL SIZE ON LUNG DEPOSITION IN PATIENTS WITH MILD ASTHMA [J].
CLAY, MM ;
CLARKE, SW .
THORAX, 1987, 42 (03) :190-194
[3]   OUTPUT CHARACTERISTICS FROM 3 MEDICAL NEBULIZERS [J].
DAHLBACK, M ;
NERBRINK, O ;
ARBORELIUS, M ;
HANSSON, HC .
JOURNAL OF AEROSOL SCIENCE, 1986, 17 (03) :563-564
[5]  
FERRON GA, 1981, J AEROSOL SCI, V16, P133
[6]   COMPARISON OF LUNG DEPOSITION OF A SOLUTION AFTER NEBULIZATION BY 3 COMMONLY USED PORTABLE NEBULIZERS [J].
FOULDS, RA ;
SMITHUIS, LOMJ .
PHARMACEUTISCH WEEKBLAD-SCIENTIFIC EDITION, 1983, 5 (02) :74-76
[7]   QUANTITATIVE DEPOSITION OF AEROSOLIZED GENTAMICIN IN CYSTIC-FIBROSIS [J].
ILOWITE, JS ;
GORVOY, JD ;
SMALDONE, GC .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1987, 136 (06) :1445-1449
[8]   BRONCHIAL HYPERREACTIVITY AFTER INHALATION OF DISTILLED WATER AND SALINE [J].
LEWIS, R ;
TATTERSFIELD, AE .
BRITISH MEDICAL JOURNAL, 1982, 284 (6308) :47-47
[9]  
LEWIS RA, 1980, CLIN SCI, V59, P12
[10]   PULMONARY DEPOSITION OF AEROSOLS BY DIFFERENT MECHANICAL DEVICES [J].
MATTHYS, H ;
KOHLER, D .
RESPIRATION, 1985, 48 (03) :269-276