CHANGES IN PERICARDIAL PRESSURE DURING THE PERINATAL-PERIOD

被引:24
作者
GRANT, DA
KONDO, CS
MALONEY, JE
WALKER, AM
TYBERG, JV
机构
[1] UNIV CALGARY,FAC MED,CALGARY T2N 1N4,ALBERTA,CANADA
[2] MONASH UNIV,MONASH UNIV CENTURE EARLY HUMAN DEV,MELBOURNE,VIC 3004,AUSTRALIA
[3] UNIV CALGARY,CARDIOVASC RES GRP,CALGARY T2N 1N4,ALBERTA,CANADA
关键词
PERICARDIUM; FETAL HEART; VENTRICULAR CONSTRAINT;
D O I
10.1161/01.CIR.86.5.1615
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. To determine how the tissues that surround the heart affect diastolic and systolic function during the perinatal period, we studied the pressure-diameter relation of the left ventricle in partially delivered fetal lambs. Methods and Results. We anesthetized (1.5-2.0% halothane, balance O2) and ventilated six pregnant ewes (142-144 days of gestation) and then partially delivered each lamb by cesarean section. Each lamb was instrumented to record left ventricular anteroposterior diameters (endocardial ultrasonic transducers), pericardial pressure (liquid-containing balloon), and left ventricular pressure (transducer-tipped catheter). Left ventricular pressure-diameter relations were recorded under three conditions: initially, with a closed chest and closed pericardium (before ventilation); second, after interruption of the umbilical circulation and 1 hour of ventilation; and finally, when the lungs and the pericardium were retracted from the heart. Pericardial pressure (recorded at a common diameter, i.e., the maximal end-diastolic diameter recorded before ventilation) decreased by 48% after 1 hour of ventilation (p<0.05). After ventilation, left ventricular anteroposterior diameters were 4-5% greater (p<0.05) at each end-diastolic pressure compared (12.5, 15.0, 17.5, and 20 mm Hg). Thus, ventilation appeared to increase left ventricular diastolic compliance. Contractility also appeared to increase after ventilation when evaluated using ventricular stroke work as a function of end-diastolic pressure as preload. When we used a more appropriate measure of preload (i.e., transmural end-diastolic pressure), ventilation did not change left ventricular diastolic compliance or contractility. Thus, left ventricular systolic function increased because of an increase in preload. Conclusions. The tissues surrounding the fetal heart significantly augment pericardial pressure and limit left ventricular preload. The initiation of ventilation reduces pericardial pressure, increases left ventricular preload, and increases left ventricular systolic function. At birth, a decrease in pericardial pressure and the resulting increase in preload may help increase left ventricular output through the Frank-Starling mechanism.
引用
收藏
页码:1615 / 1621
页数:7
相关论文
共 33 条
[1]   BIOPHYSICS OF THE DEVELOPING HEART .3. A COMPARISON OF THE LEFT-VENTRICULAR DYNAMICS OF THE FETAL AND NEONATAL LAMB HEART [J].
ANDERSON, PAW ;
MANRING, A ;
GLICK, KL ;
CRENSHAW, CC .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1982, 143 (02) :195-203
[2]   THE INUTERO LEFT-VENTRICLE OF THE FETAL SHEEP - THE EFFECTS OF ISOPRENALINE [J].
ANDERSON, PAW ;
FAIR, EC ;
KILLAM, AP ;
NASSAR, R ;
MAINWARING, RD ;
ROSEMOND, RL ;
WHYTE, LM .
JOURNAL OF PHYSIOLOGY-LONDON, 1990, 430 :441-452
[3]   DEVELOPMENTAL-CHANGES IN CARDIAC CONTRACTILITY IN FETAL AND POSTNATAL SHEEP - INVITRO AND INVIVO [J].
ANDERSON, PAW ;
GLICK, KL ;
MANRING, A ;
CRENSHAW, C .
AMERICAN JOURNAL OF PHYSIOLOGY, 1984, 247 (03) :H371-H379
[4]   THE EFFECT OF HEART-RATE ON INUTERO LEFT-VENTRICULAR OUTPUT IN THE FETAL SHEEP [J].
ANDERSON, PAW ;
GLICK, KL ;
KILLAM, AP ;
MAINWARING, RD .
JOURNAL OF PHYSIOLOGY-LONDON, 1986, 372 :557-573
[5]   CLEARANCE OF LIQUID FROM LUNGS OF NEWBORN RABBITS [J].
BLAND, RD ;
MCMILLAN, DD ;
BRESSACK, MA ;
DONG, L .
JOURNAL OF APPLIED PHYSIOLOGY, 1980, 49 (02) :171-177
[6]  
DAVIS JA, 1964, BIOL NEONATORUM, V7, P129
[7]   MECHANISM OF DECREASED RIGHT AND LEFT-VENTRICULAR END-DIASTOLIC VOLUMES DURING CONTINUOUS POSITIVE-PRESSURE VENTILATION IN DOGS [J].
FEWELL, JE ;
ABENDSCHEIN, DR ;
CARLSON, CJ ;
RAPAPORT, E ;
MURRAY, JF .
CIRCULATION RESEARCH, 1980, 47 (03) :467-472
[8]  
GILBERT R D, 1982, Journal of Developmental Physiology (Eynsham), V4, P299
[9]   CONTROL OF FETAL CARDIAC-OUTPUT DURING CHANGES IN BLOOD-VOLUME [J].
GILBERT, RD .
AMERICAN JOURNAL OF PHYSIOLOGY, 1980, 238 (01) :H80-H86
[10]   FACTORS WHICH AFFECT DIASTOLIC PRESSURE-VOLUME CURVE [J].
GLANTZ, SA ;
PARMLEY, WW .
CIRCULATION RESEARCH, 1978, 42 (02) :171-180