FAR-INFRARED LASER DIAGNOSTICS ON THE HT-6M TOKAMAK

被引:28
作者
GAO, X
LU, HJ
GUO, QL
WAN, YX
TONG, XD
机构
[1] Institute of Plasma Physics, Academia Sinica, Hefei, Anhui 230031
关键词
D O I
10.1063/1.1146431
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A multichannel far-infrared (FIR) hydrogen cyanide (HCN) laser interferometer was developed to measure plasma electron density profile on the HT-6M tokamak. The structure of the seven-channel FIR laser interferometer is described. The laser source used in the interferometer was a continuous-wave glow discharge HCN laser with a cavity length of 3.4 m and power output of about 100 mW at 337 μm. The detection sensitivity was 1/15 fringe with a temporal resolution of 0.1 ms. Experimental results were measured by the seven-channel FIR HCN laser interferometer with edge Ohmic heating, a pumping limiter, and ion cyclotron resonant heating on the HT-6M tokamak are reported. © 1995 American Institute of Physics.
引用
收藏
页码:139 / 142
页数:4
相关论文
共 4 条
[1]   EDGE OHMIC HEATING EXPERIMENT ON HT-6M TOKAMAK [J].
GAO, X ;
FAN, SP ;
LI, JG ;
MENG, YD ;
LUO, JR ;
YIN, FX ;
ZENG, L ;
DING, LC ;
LIN, BL ;
ZHANG, W ;
HAN, YQ ;
TONG, XD ;
LUO, LC ;
GONG, XZ ;
JIANG, JG ;
WU, MJ ;
YIN, F .
CHINESE PHYSICS LETTERS, 1994, 11 (03) :161-164
[2]  
GAO X, 1993, THESIS ASIPP
[3]  
TONG XD, 1988, ACTA OPT SINICA, V8, P933
[4]  
VERON D, 1979, INFRARED MILLIMETER, V2