X-RAY SPECTRAL RECONSTRUCTION FROM ATTENUATION DATA USING NEURAL NETWORKS

被引:17
作者
BOONE, JM
机构
[1] Division of Radiological Physics, Department of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania
关键词
D O I
10.1118/1.596495
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An artificial neural network using input data derived from attenuation measurements was trained to generate spectral profiles (relative number of photons versus energy). Once the relative spectral distribution is reconstructed, absolute spectra (number of photons per unit exposure versus energy) can be calculated. A neural network was trained on spectra generated mathematically using the Birch-Marshall model, combined with attenuation data, calculated from the spectra by numerical integration. Whereas attenuation data can be calculated in a straightforward manner from the x-ray spectra, the reverse is not true. Several neural networks were successfully taught to reconstruct the spectra, given the attenuation data. The networks were tested using kV/inherent filtration combinations that were not in the training set, and the performance of the reconstruction was excellent. Noise in the attenuation data was simulated to test the effects of noise propagation in the reconstruction. The effects of network architecture and data averaging on noise propagation were investigated. Experimentally determined spectral data compiled by Fewell were also used to train a neural network, and the results of the reconstruction were also found to be excellent. © 1990, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:647 / 654
页数:8
相关论文
共 16 条
[1]   A LAPLACE TRANSFORM PAIR MODEL FOR SPECTRAL RECONSTRUCTION [J].
ARCHER, BR ;
WAGNER, LK .
MEDICAL PHYSICS, 1982, 9 (06) :844-847
[2]  
Attix FH., 1986, INTRO RADIOLOGICAL P, P358
[3]   X-RAY-SPECTRA VS ATTENUATION DATA - A THEORETICAL-ANALYSIS [J].
BAIRD, LC .
MEDICAL PHYSICS, 1981, 8 (03) :319-323
[4]   COMPUTATION OF BREMSSTRAHLUNG X-RAY-SPECTRA AND COMPARISON WITH SPECTRA MEASURED WITH A GE(LI) DETECTOR [J].
BIRCH, R ;
MARSHALL, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (03) :505-517
[5]   THE 3 PARAMETER EQUIVALENT SPECTRA AS AN INDEX OF BEAM QUALITY [J].
BOONE, JM .
MEDICAL PHYSICS, 1988, 15 (03) :304-310
[6]   NEURAL NETWORKS IN RADIOLOGY - AN INTRODUCTION AND EVALUATION IN A SIGNAL-DETECTION TASK [J].
BOONE, JM ;
SIGILLITO, VG ;
SHABER, GS .
MEDICAL PHYSICS, 1990, 17 (02) :234-241
[7]  
FEWELL TRF, 1981, HHS818162 PUBL
[8]   SIMULATION STUDIES OF 4-MV X-RAY SPECTRAL RECONSTRUCTION BY NUMERICAL-ANALYSIS OF TRANSMISSION DATA [J].
HUANG, PH ;
KASE, KR ;
BJARNGARD, BE .
MEDICAL PHYSICS, 1982, 9 (05) :695-702
[9]  
JOHNS HE, 1983, PHYSICS RADIOLOGY
[10]  
KEREIAKES JG, 1980, HDB RAD DOSES NUCLEA