A BIODEGRADABLE COMPOSITE ARTIFICIAL TENDON

被引:17
作者
DAVIS, PA
HUANG, SJ
AMBROSIO, L
RONCA, D
NICOLAIS, L
机构
[1] UNIV CONNECTICUT,INST MAT SCI,STORRS,CT 06268
[2] NAPLES UNIV,DEPT MAT PROD & ENGN,I-80125 NAPLES,ITALY
关键词
D O I
10.1007/BF00705368
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The development of a completely biodegradable composite artificial tendon prosthesis that mimics the structure and stress-strain response of natural tendon is presented. The artificial tendon is a composite of water-swollen poly(2-hydroxyethylmethacrylate)/poly(caprolactone) blend hydrogel matrix reinforced with poly(lactic acid) fibres.
引用
收藏
页码:359 / 364
页数:6
相关论文
共 59 条
[1]   MECHANICAL BEHAVIOUR OF TENDON IN VITRO - A PRELIMINARY REPORT [J].
ABRAHAMS, M .
MEDICAL & BIOLOGICAL ENGINEERING, 1967, 5 (05) :433-+
[2]  
ALEXANDER H, 1979, T NEB BIOENG C, V7, P400
[3]  
ALEXANDER H, 1979, 25TH ANN M ORTH RES
[4]  
ALEXANDER H, 1978, 10TH ANN INT BIOM S
[5]   RECONSTRUCTION OF CANINE ACHILLES AND PATELLAR TENDONS USING DACRON MESH SILICONE PROSTHESIS .1. CLINICAL AND BIOCOMPATIBILITY EVALUATION [J].
AMSTUTZ, HC ;
COULSON, WF ;
DAVID, E .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1976, 10 (01) :47-59
[6]  
ARAGONA J, 1981, CLIN ORTHOP RELAT R, V160, P268
[7]  
ASHLEY F L, 1959, Plast Reconstr Surg Transplant Bull, V23, P526, DOI 10.1097/00006534-195905000-00006
[8]  
BADER KF, 1968, ARCH SURG-CHICAGO, V97, P406
[9]  
BAER E, 1975, MEKH POLIM, V6, P1051
[10]   IN-VIVO TENDON TENSION AND BONE STRAIN MEASUREMENT AND CORRELATION [J].
BARNES, GRG ;
PINDER, DN .
JOURNAL OF BIOMECHANICS, 1974, 7 (01) :35-42