MEASUREMENT OF 3-DIMENSIONAL SHOULDER MOVEMENT BY AN ELECTROMAGNETIC SENSOR

被引:35
作者
JOHNSON, GR
ANDERSON, JM
机构
[1] Department of Mechanical, Materials and Manufacturing Engineering, University of Newcastle upon Tyne
关键词
joints; measurement; movement; Shoulder;
D O I
10.1016/0268-0033(90)90015-X
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
As a consequence of the difficulty in the measurement of three-dimensional motion in the clinical setting, the assessment of the shoulder joint is performed using movements about a single axis, for example, abduction, flexion and humeral rotation. The development of the Isotrak, an electromagnetic movement sensor, has made the measurement of spatial motion possible; this instrurhent has been used to measure movement at the shoulder joint. In addition to the difficulty of measurement, there is the problem of representing three-dimensional movements graphically. This paper demonstrates the inadequacy of the traditional system of clinical angles and shows that a system of spherical polar coordinates is better suited to display complex movement. Isotrak is therefore thought to be suitable for the clinical assessment of shoulder movement and this system allows for the graphical description of complex movements which have previously been difficult to define, despite the fact that it may be less easy, initially, to interpret than the traditional system. © 1990.
引用
收藏
页码:131 / 136
页数:6
相关论文
共 13 条
[1]  
Nicol, Measurement of joint motion, Clinical Rehabilitation, 3, pp. 1-9, (1989)
[2]  
American Academy of Orthopaedic Surgeons, Joint motion: method of measuring and recording, (1965)
[3]  
Clarke, Willis, Fish, Nichols, Assessment of movement at the glenohumeral joint, Orthopaedics, 7, pp. 55-71, (1974)
[4]  
Boone, Azen, Normal range of motion of joints in male subjects, J Bone Joint Surg, 61 A, pp. 756-795, (1979)
[5]  
Greenwood, Principles of Dynamics, (1965)
[6]  
Langrana, Spatial kinematic analysis of the upper extremity using a biplanar videotaping method, J Biomech Eng, 103, pp. 11-17, (1981)
[7]  
Engin, Peindl, Berme, Kaleps, Kinematic and force data collection in biomechanics by means of sonic emitters-1.: kinematic data collection methodology, J Biomech Eng, 106, pp. 204-211, (1984)
[8]  
Kapandji, The Shoulder, Clin Rheum Dis, 8, pp. 595-616, (1982)
[9]  
Engin, Chen, Statistical database for the biomechanical properties of the Human Shoulder complex-1: kinematics of the shoulder complex, J Biomech Eng, 108, pp. 215-221, (1986)
[10]  
Hindle, Pearcy, Rotational mobility of the human back in forward flexion, J Biomed Eng, 11, pp. 219-223, (1989)